Experimental Evaluation of the Ventilation Effectiveness of Corner Stratum Ventilation in an Office Environment
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-8349-6659
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-2023-689x
2019 (English)In: Buildings, ISSN 2075-5309, E-ISSN 2075-5309, Vol. 9, no 7, article id 169Article in journal (Refereed) Published
Abstract [en]

An experimental study was conducted in a room resembling an office in a laboratory environment. The study involved investigating the ability of corner-placed stratum ventilation in order to evaluate the ventilation’s effectiveness and local thermal comfort. At fixed positions, the air temperature, air velocity, turbulence intensity, and tracer gas decay measurements were carried out. The results show that corner-placed stratum ventilation behaves very similar to a mixing ventilation system when considering air change effectiveness. The performance of the system was better at lower supply air flow rates for heat removal effectiveness. For the heating cases, the draught rates were all very low, with the maximum measured value of 12%. However, for the cooling cases, the maximum draught rate was 20% and occurred at ankle level in the middle of the room.

Place, publisher, year, edition, pages
MDPI, 2019. Vol. 9, no 7, article id 169
Keywords [en]
air change effectiveness; air exchange efficiency; ventilation effectiveness; draught rate; temperature effectiveness
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-30433DOI: 10.3390/buildings9070169ISI: 000478645000003Scopus ID: 2-s2.0-85070072942OAI: oai:DiVA.org:hig-30433DiVA, id: diva2:1337487
Available from: 2019-07-15 Created: 2019-07-15 Last updated: 2019-08-23Bibliographically approved

Open Access in DiVA

fulltext(2802 kB)25 downloads
File information
File name FULLTEXT01.pdfFile size 2802 kBChecksum SHA-512
ad04e3d802a744c70f22927eb639c40029ded9838df9d14ba460d3a150a9aa127a27b705d720a4992c252e3d71f99e76e02a56da4792224070b59035c4f6a68d
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records BETA

Ameen, ArmanCehlin, Mathias

Search in DiVA

By author/editor
Ameen, ArmanCehlin, Mathias
By organisation
Energy Systems and Building Technology
In the same journal
Buildings
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 25 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 52 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf