Assessment of Airflows in a School Building with Mechanical Ventilation Using Passive Tracer Gas Method
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.ORCID-id: 0000-0002-5822-4838
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.ORCID-id: 0000-0001-9076-0801
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Miljöteknik.ORCID-id: 0000-0002-8985-2562
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Division of Energy Systems, Department of Management and Engineering, Linköping Unviersty, Linköping, Sweden.ORCID-id: 0000-0003-3472-4210
2017 (engelsk)Inngår i: Mediterranean Green Buildings & Renewable Energy: Selected Papers from the World Renewable Energy Network’s Med Green Forum / [ed] Sayigh, Ali, Springer, 2017, 1, s. 619-631Kapittel i bok, del av antologi (Fagfellevurdert)
Abstract [en]

The focus of this study is to assess the airflows in a school building built in 1963 in Gävle, Sweden, which is subject to energy conservation measures (ECMs) in a forthcoming renovation. Today, the school building is mainly ventilated by several mechanical ventilation systems, which are controlled by a constant air volume (CAV) strategy. Schedules and presence sensors impose a high operation mode during the day and a low operation mode at night, on weekends and on holidays. The homogeneous tracer gas emission method with passive sampling is used to measure the average local mean age of air (τ) during different operation modes. Temperature, relative humidity and CO2 concentration are simultaneously measured. The calculated relative uncertainty for the average local mean age of air in every measured point is approx. ±20 %. The results during low operation mode show an average value of τ of approx. 8.51 h [corresponding to 0.12 air changes per hour (ACH)], where τ in various zones ranges between 2.55 and 16.37 h (indicating 0.06–0.39 ACH), which is related to the unintentional airflow in the school. The results during mixed operation mode show an average value of τ of approx. 4.60 h (0.22 ACH), where τ in various zones ranges between 2.00 and 8.98 h (0.11–0.50 ACH), which is related to both unintentional and intentional airflows in the school. Corridors, basement and attic rooms and entrances have lower τ compared to classrooms, offices and other rooms. High maximums of the CO2 concentration in some rooms indicate an imbalance in the mechanical ventilation systems. During a regular school week of mixed operation, which includes both high and low operation modes, it is found that mainly the low operation modes show up in the results. The dynamics of the highly varying airflows in the building cannot be identified using the passive sampling technique.

sted, utgiver, år, opplag, sider
Springer, 2017, 1. s. 619-631
Emneord [en]
Homogeneous tracer gas emission technique, Local mean age of air, Air change rate, Air leakage, School building
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-24006DOI: 10.1007/978-3-319-30746-6_47Scopus ID: 2-s2.0-85029047826Libris ID: 19983693ISBN: 978-3-319-30745-9 (tryckt)ISBN: 978-3-319-30746-6 (digital)OAI: oai:DiVA.org:hig-24006DiVA, id: diva2:1095276
Merknad

Entire publication doi: 10.1007/978-3-319-30746-6

Tilgjengelig fra: 2017-05-12 Laget: 2017-05-12 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Steen Englund, JessikaAkander, JanBjörling, MikaelMoshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Steen Englund, JessikaAkander, JanBjörling, MikaelMoshfegh, Bahram
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 156 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf