Long term ventilation variation in two naturally ventilated Stockholm dwellings
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Ventilation och Luftkvalité)
2005 (engelsk)Inngår i: Indoor Air 2005: Proceedings of the 10th International Conference in Indoor Air Quality and Climate, vol 1-5, 2005, s. 3239-3243Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Passive tracer gas measurements of ventilation were performed in a single-family house and in a flat in Stockholm during four consecutive winter seasons. Measured averages of ACH data are reported for 47 two-week periods for the two naturally ventilated dwellings. The variation of ventilation is discussed in terms of variation in the ventilation driving forces induced by inside-outside temperature differences. The detached house shows a slightly better correlation between ACH and indoor-outside temperature difference than the town flat. It is concluded that

the correlations are not good enough for predictive use for either dwelling. Therefore it does not seem possible to “normalise” ventilation measurement data, obtained during one time period with a specific weather condition, to what would be expected during a period with “normal” weather conditions. A possible reason for the lack of good correlation between ACH and natural driving forces is a highly variable influence from occupant behaviour.

sted, utgiver, år, opplag, sider
2005. s. 3239-3243
Emneord [en]
ventilation, passive tracer gas, dwellings, field measurement
Identifikatorer
URN: urn:nbn:se:hig:diva-928ISBN: 978-7-89494-830-4 (tryckt)OAI: oai:DiVA.org:hig-928DiVA, id: diva2:117590
Konferanse
10th International Conference on Indoor Air Quality and Climate (Indoor Air 2005) Beijing, China, Sep 04-09, 2005
Tilgjengelig fra: 2007-12-04 Laget: 2007-12-04 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Stymne, Hans

Søk i DiVA

Av forfatter/redaktør
Stymne, Hans
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 128 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf