hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Use of a Peltier Element to Increase Time of Wetness of Unglazed Solar Collector Specimens in a Natural Field Exposure Test
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för byggnadskvalitet. (Materialteknik)
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för byggnadskvalitet. (Materialteknik)ORCID-id: 0000-0001-9076-0801
2008 (engelsk)Inngår i: Durability of Building Materials & Components 11 (11DBMC), Istanbul, Turkey, 11-14 May 2008, 2008, s. 1169-1175Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

In accelerated testing, material specimens are exposed to completely artificial environments, where exposure to individual degradation agents is enhanced. In contrast, field-testing exposes specimens to multiple degradation agents. When performing a semi-natural test, the influence of a selected degradation agent may be increased while the specimen is still situated in its natural environment. Moisture is such an agent. In an experimental set-up for evaluating long-term optical performance of an building integrated Unglazed Solar Collector, a sub-task was to increase Time of Wetness (TOW) for several collector specimens for two reasons: to “simulate” an active cooling of the component as is the case for solar collectors; and to assess the role of TOW on optical degradation of the solar collector. Specimen cooling and increase in TOW was achieved by utilisation of a Direct-Air Peltier Element. TOW was estimated through measurements with WETCORR sensors (monitoring surface temperatures and moisture) and climate parameters (temperature and relative humidity) at site. At this particular test site in Gävle, Sweden, TOW was more than doubled in comparison to non-cooled surfaces. The Peltier Element proved to be inexpensive and flexible for this purpose.

sted, utgiver, år, opplag, sider
2008. s. 1169-1175
Emneord [en]
Peltier Element, time of wetness, semi-natural environment, optical durability.
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-1773ISBN: 978-975-561-328-4 (tryckt)OAI: oai:DiVA.org:hig-1773DiVA, id: diva2:118435
Konferanse
11DBMC, Istanbul, Turkey, 11-14 May 2008
Tilgjengelig fra: 2008-05-22 Laget: 2008-05-22 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Article available at Baufachinformation.de

Personposter BETA

Stojanovic, BojanAkander, Jan

Søk i DiVA

Av forfatter/redaktør
Stojanovic, BojanAkander, Jan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 101 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf