Effect of Particulate Air Cleaners on the Content of airborne Dust and Cat Allergen in Classrooms
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Ventilation och lutkvalitet)ORCID-id: 0000-0002-0337-8004
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för byggnadskvalitet.
2004 (engelsk)Inngår i: Roomvent 2004: 9th international conference on air distribution in rooms, 2004Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Electrostatic air cleaners (precipitators) were tested in four classrooms during ordinary lessons for four weeks. Airborne dust in the classrooms was collected on filters using two different kinds of samplers: IOM-sampler and a new kind of ionizing sampler. The amount of collected dust was evaluated by visual inspection (“filter blackening”) and the content of cat allergen was measured using an amplified ELISA assay. It was found that the filter blackening was 64% lower when the air cleaners were active than when they where inactive (p<0.001). This suggests that the air cleaners were effective in reducing the content of airborne particulate matter. The reduction in cat allergen appeared however to be less substantial. The variance of the allergen data was unexpectedly large, presumably due to relatively few allergen-carrying particles in the sampled air. It is believed that larger sampling volumes are needed to get more reliable data of airborne cat allergen in spaces where the allergen is emitted indirectly.

sted, utgiver, år, opplag, sider
2004.
Emneord [en]
Air cleaning, Allergy, Allergens, Air quality, Classrooms, Schools, Ventilation, Cat allergen, Particles
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-2730ISBN: 972-97973-2-3 (tryckt)OAI: oai:DiVA.org:hig-2730DiVA, id: diva2:119392
Konferanse
Roomvent 2004, Coimbra, Portugal, 5-8 September 2004
Tilgjengelig fra: 2007-12-04 Laget: 2007-12-04 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Mattsson, MagnusStojanovic, Bojan

Søk i DiVA

Av forfatter/redaktør
Mattsson, MagnusStojanovic, Bojan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 1460 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf