hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Characteristics of jugular bulb oxygen saturationin patients after cardiac arrest: A prospective study
Department of Surgical Sciences - Anaestesiology & Intensive Care, Uppsala University, Uppsala Sweden.ORCID-id: 0000-0003-2492-8666
Department of Surgical Sciences - Anaestesiology & Intensive Care, Uppsala University, Uppsala Sweden.
Department of Surgical Sciences - Anaestesiology & Intensive Care, Uppsala University, Uppsala Sweden.
Department of Surgical Sciences - Anaestesiology & Intensive Care, Uppsala University, Uppsala Sweden.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Acta Anaesthesiologica Scandinavica, ISSN 0001-5172, E-ISSN 1399-6576, Vol. 62, nr 9, s. 1237-1245Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND:

Using cerebral oxygen venous saturation post-cardiac arrest (CA) is limited because of a small sample size and prior to establishment of target temperature management (TTM). We aimed to describe variations in jugular bulb oxygen saturation during intensive care in relation to neurological outcome at 6 months post- CA in cases where TTM 33°C was applied.

METHOD:

Prospective observational study in patients over 18 years, comatose immediately after resuscitation from CA. Patients were treated with TTM 33°C M and received a jugular bulb catheter within the first 26 hours post-CA. Neurological outcome was assessed at 6 months using the Cerebral Performance Categories (CPC) and dichotomized into good (CPC 1-2) and poor outcome (CPC 3-5).

RESULTS:

Seventy-five patients were included and 37 (49%) patients survived with a good outcome at 6 months post-CA. No differences were found between patients with good outcome and poor outcome in jugular bulb oxygen saturation. Higher values were seen in differences in oxygen content between central venous oxygen saturation and jugular bulb oxygen saturation in patients with good outcome compared to patients with poor outcome at 6 hours (12 [8-21] vs 5 [-0.3 to 11]% P = .001) post-CA. Oxygen extraction fraction from the brain illustrated lower values in patients with poor outcome compared to patients with good outcome at 96 hours (14 [9-23] vs 31 [25-34]% P = .008).

CONCLUSIONS:

Oxygen delivery and extraction differed in patients with a good outcome compared to those with a poor outcome at single time points. Based on the present findings, the usefulness of jugular bulb oxygen saturation for prognostic purposes is uncertain in patients treated with TTM 33°C post-CA.

sted, utgiver, år, opplag, sider
2018. Vol. 62, nr 9, s. 1237-1245
Emneord [en]
cardiac arrest, intensive care, jugular bulb saturation, neurological outcome, prognostication, target temperature management
HSV kategori
Forskningsprogram
inget Strategiskt forskningsområde (SFO)
Identifikatorer
URN: urn:nbn:se:hig:diva-26622DOI: 10.1111/aas.13162ISI: 000443673500008PubMedID: 29797705Scopus ID: 2-s2.0-85047479161OAI: oai:DiVA.org:hig-26622DiVA, id: diva2:1209999
Merknad

Funding: Department of Surgical Sciences-Anaesthesiology & Intensive Care, Uppsala University, Sweden

Tilgjengelig fra: 2018-05-25 Laget: 2018-05-25 Sist oppdatert: 2020-03-23bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Kristofferzon, Marja-Leena

Søk i DiVA

Av forfatter/redaktør
Wallin, EwaKristofferzon, Marja-Leena
Av organisasjonen
I samme tidsskrift
Acta Anaesthesiologica Scandinavica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 46 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf