Experimental investigation of ventilation performance of corner placed stratum ventilation in an office environment
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap, Energisystem och byggnadsteknik.
2019 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 80 poäng / 120 hpOppgave
Hållbar utveckling
Uppsatsen/examensarbetet handlar till övervägande del om hållbar utveckling enligt högskolans kriterier
Abstract [en]

Energy use in buildings account for about one third of the total global energy supply and contributes as much as 30% of the anthropogenic greenhouse gas emissions. It is estimated that energy use in buildings will increase to 67% by 2030. The need for better thermal comfort and air quality in indoor environments is the leading cause for high energy use in buildings.  Heating, ventilation and air conditioning systems take up about 50% of the total energy use in buildings which is about 10-20% of the national energy use in most developed countries. The development and adoption of sustainable ventilation systems is a viable solution to mitigate climate change and curtail carbon emissions.

The experimental study was conducted in a room resembling a modern office in a laboratory environment. The study involved investigating the ability of the system to provide cooling and heating. Concentration decay tracer gas technique using Sulphur hexafluoride (SF6) gas was used to determine the local air change index and air change efficiency in the room. Low-velocity omni-directional thermistor anemometer type CTA88 were used to measure the air velocity and temperature in the room. Smoke was used to visualise the flow patterns created in the room.  The climate chamber was used to mimic climatic conditions in winter. Fifteen cases were investigated with five air flow rates set points (30, 40, 50, 60 and 70 l/s) at three supply air temperatures, i.e., 17.6 °C, 21.0 °C and 25.3 °C.

The results of the local air change index and air change efficiency for the nominal supply temperature of 17.6 °C showed that the system had strong characteristics of a mixing ventilation system. At the supply air temperature of 21.0 °C, the performance of the system deteriorated slightly to below that of a mixing ventilation system and could not satisfactorily provide heating at supply temperature of 25.3 °C. Better performance of the system at all supply air temperature setpoints was observed at lower airflow rates. At all supply air temperature setpoints, relatively higher degree of temperature stratification was observed at lower supply. The draught rate levels decreased with increase in supply air temperature and height. The location of the air inlet terminals in relation to the workstations had significant effect on the performance of the system. The stratum ventilation system did not work efficiently because the air streams were heavily mixed before reaching the occupants.

sted, utgiver, år, opplag, sider
2019. , s. 82
Emneord [en]
Stratum ventilation, local air change index, air change efficiency, ventilation effectiveness, draught rate, percentage dissatisfied, heat removal effectiveness
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-29710OAI: oai:DiVA.org:hig-29710DiVA, id: diva2:1321430
Fag / kurs
Energy systems
Utdanningsprogram
Energy systems – master’s programme (two years)
Presentation
2019-06-04, 91:274, University of Gävle, Kungsbacksvägen 47, 80176, Gävle, 23:28 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2019-06-11 Laget: 2019-06-07 Sist oppdatert: 2019-06-11bibliografisk kontrollert

Open Access i DiVA

fulltext(2996 kB)66 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2996 kBChecksum SHA-512
d28812de493448fc43407d13c6aaed227a5b2d9c982a645e22567a6cbc836ad8f4c31b1ce9c153cf414fb1dd60af9e5bcbe1bae12dae34018d67b72457645417
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 66 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 89 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf