SELECTIVE NON-CATALYTIC REDUCTION SYSTEM
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för elektroteknik, matematik och naturvetenskap, Elektronik.
2020 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

The aim of this thesis is to develop a Selective Non-Catalytic Reduction (SNCR) system which is based on a control system to keep NOx emissions from combustion by maximum 27 kg/h urea consumption and then perform commissioning on the site. The NOx value in the combustion is around 220 mg/Nm3 under 100% laud. The SNCR system will decrease the NOx value in the combustion till around 180-190 mg/Nm3 . The system injects the amount of urea directly into the combustion which creates chemical reaction and as a result of NOx decreases. The system will consist of a storage tank, pump module for reduction agent (PMR), standardized pump module for softened water (PMW), pump module for filling (PMF), two injectors and a cabinet for control and management (CMM). The control system made of PLC (Siemens) intelligence and a HMI (CitectSCADA) for local operation. The system is a closed-loop control system where it gets signals continuously from NOx analyzer in the combustion and PID controller the process variables and injecting amount of urea to keep the NOx under set point. The HMI provides a robust capability for visualization controls the entire system. The communication with the modules is performed via bus cables from the control and management cabinet. The communication between the control system and the plant is done via Profibus. The supervision and daily operation can be done both from the operator panel and in the control room. The SNCR system has been installed successfully and the system manage to reduce the NOx value from 220 mg/Nm3 till around 190 mg/Nm3 by around 21.7 kg/h urea consumption.

sted, utgiver, år, opplag, sider
2020. , s. 40
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-31983OAI: oai:DiVA.org:hig-31983DiVA, id: diva2:1410958
Eksternt samarbeid
Sweco Industry AB
Fag / kurs
Electronics
Utdanningsprogram
Electronics/Automation – master's programme (two years) (sv or eng)
Veileder
Examiner
Tilgjengelig fra: 2020-03-02 Laget: 2020-03-02 Sist oppdatert: 2020-03-02bibliografisk kontrollert

Open Access i DiVA

fulltext(1503 kB)572 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1503 kBChecksum SHA-512
5c49d199b75a1ac5b0ceb37bc5b0892e7046b4e27499842a4a29e0346f11f15822d8d776ed3d56ef07d3640720c5126089bfd2916c39eaf85f4f9819a2adfdf0
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 581 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 382 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf