 The Indoor Climate of a Naturally Ventilated Church
Högskolan i Gävle, Institutionen för matematik, natur- och datavetenskap, Ämnesavdelningen för naturvetenskap. (Kemi)ORCID-id: 0000-0002-8985-2562
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Inomhusmiljö)
Pentiaq AB.
2009 (engelsk)Inngår i: Healthy Buildings 2009, Sept 13-18, Syracuse, NY USA, IAQ , 2009, s. 1-4Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

 

The indoor air climate of a church, with a total building volume of 9500 m3, was investigated from January to October, 2008. During this time, infiltration and ventilation measurements were performed at four periods ranging from 17 to 45 days. The local mean age of air was determined in several locations at different heights using passive samplers and homogeneous emission of PFTs. In addition, the temperature and relative humidity was measured at selected locations. The total infiltration of fresh air into the church was found to be mainly driven by the difference between indoor and outdoor temperature. The rate of infiltration ranges from 780 m3/h (deltat=14.8 degrees C) in January to 240 m3/h (deltat=3.5 degrees C) in August. The local mean age of air in the upper and lower air volumes were found to be roughly equal, both during the heating season and in the summer. This indicates that the air volume in the church is well-mixed throughout the year. Transient measurements to assess the effects of doors opening in the summer were also performed using pumped sampling.

sted, utgiver, år, opplag, sider
IAQ , 2009. s. 1-4
Emneord [en]
Air change rate, Church, relative humidity, temperature, natural ventilation
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-5373OAI: oai:DiVA.org:hig-5373DiVA, id: diva2:234398
Prosjekter
KemiTilgjengelig fra: 2009-10-13 Laget: 2009-09-08 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

fulltekst(172 kB)395 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 172 kBChecksum SHA-512
953e3bb632d97cb21ab2d1a6a4c6d9d62a89ea24977ab986c728d6fc7ca21843e252365a9ffc7249c917e9873a50a121244698d86eaef0d0600a78b96fc0d7d1
Type fulltextMimetype application/pdf

Personposter BETA

Björling, MikaelStymne, Hans

Søk i DiVA

Av forfatter/redaktør
Björling, MikaelStymne, Hans
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 395 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 437 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf