Design of a ventilation system for carbon dioxide reduction in two gym rooms
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
2013 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

This project is mainly focused on the improving and design of the ventilation system of two rooms at different levels of a gym (Friskis and Svettis in Gävle, Sweden) to reduce the  concentration to never be higher than 1000 ppm.

For this purpose, several field measurements were performed in different locations and situations. Two main measurements were necessary. On one hand, the  level in different parts of the rooms during different activities. On the other hand, the air flow through the inlet and outlet ducts of the ventilation system. It was also important to take into account the indoor temperature and humidity. These measurements were enough to analyze the failures of the system and to recognize the worst points of each room.

Comparing both rooms, the necessity of changing the ventilation system in one of these rooms was much higher, due to there were measured  values up to 3000 ppm during a typical day in the gym.

With this information the consequences of high CO2 levels in human people were analyzed. Among various ventilation systems, displacement ventilation system was proposed as the new design. Theoretical calculations were made to reach to the value of 31.8  in the air change rate (ACH), which was the necessary value for the new design to keep the carbon dioxide level under 1000 ppm.

sted, utgiver, år, opplag, sider
2013. , s. 73
Emneord [en]
Ventilation system, Displacement ventilation system, Carbon dioxide
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-14801OAI: oai:DiVA.org:hig-14801DiVA, id: diva2:634146
Fag / kurs
Energy systems
Veileder
Examiner
Tilgjengelig fra: 2013-07-01 Laget: 2013-06-28 Sist oppdatert: 2013-07-01bibliografisk kontrollert

Open Access i DiVA

Ander Barroeta Master Thesis(2746 kB)1279 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2746 kBChecksum SHA-512
655f6a6a6a8836c9994415bf19888963d089798918a96e8d6f90812c0d052b1e1ba1776723a226a75fdb32485255fb281b05361473aeb903d70529b6a16f0a76
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1279 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1100 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf