hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fan pressurization method for measuring air leakage in churches – wind and stack induced uncertainties
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. (Indoor environment)ORCID-id: 0000-0002-0337-8004
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. (Indoor environment)
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet. Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet. Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet.
Vise andre og tillknytning
2013 (engelsk)Inngår i: Conference proceedings: Cultural heritage preservation – 3rd European Workshop on Cultural Heritage Preservation / [ed] A. Troi and E. Luchi., 2013, s. 63-68Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The air leakage of the building envelope of ancient churches and other historical and monumental buildings has impact on energy consumption, thermal comfort, humidity and indoor surface soiling. To measure the air leakage in such large and naturally ventilated single-zone buildings is however challenging, especially due to wind and buoyancy (stack) induced disturbances. This study describes experiences in this regard, attainedat field tests where the fan pressurization technique (“Blower door”) was employed. Reference is made to the European test standard EN 13829. Also results of wind-tunnel tests are utilized. It is shown that both buoyancy and wind at commonly occurring conditions can cause significant uncertainty in fan pressurization tests, and that some of the directions in the standard might need to be strengthened or amended. While the uncertainty in measured air leakage rate at the standard (high) pressure of 50 Pa may be small, the predictions of the air leakage rate occurring at realistically (low) indoor-outdoor pressures tend to suffer from significant uncertainty. That uncertainty is then conveyed to later utilizations of the test results, e.g. building energy modeling and prediction. It is also shown that the wind induced pressure at buildings like churches extends a considerable way out into the surroundings of the building; in the order of two times the building height. This has particular importance when choosing a reference point for outdoorpressure measurement.

sted, utgiver, år, opplag, sider
2013. s. 63-68
Emneord [en]
Fan pressurization, Blower door, Large buildings, Churches, Wind effects, Stack effects
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-15409ISBN: 978-88-88307-26-8 (tryckt)OAI: oai:DiVA.org:hig-15409DiVA, id: diva2:650929
Konferanse
Cultural heritage preservation – 3rd European Workshop on Cultural Heritage Preservation (EWCHP), Bozen, Italy, September 16-17, 2013
Prosjekter
Church project
Forskningsfinansiär
Swedish Energy Agency, 2011-002440Tilgjengelig fra: 2013-09-24 Laget: 2013-09-24 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Mattsson, MagnusSandberg, MatsClaesson, LeifLindström, SvanteHayati, Abolfazl

Søk i DiVA

Av forfatter/redaktør
Mattsson, MagnusSandberg, MatsClaesson, LeifLindström, SvanteHayati, Abolfazl
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 992 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf