Sänkning av returtemperatur: Identifiering av kundanläggningar som påverkar returtemperaturen negativt
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
2014 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [sv]

 

Sandviken Energi producerar ungefär 220 GWh fjärrvärme och 20 GWh el varje år vid sin produktionsanläggning i Björksätra Sandviken. För att effektivisera denna produktion är en av de bättre lösningarna en sänkning av returtemperaturen.

En sänkt returtemperatur innebär effektivare rökgaskondensering, mindre förluster till mark, sänkt pumpdrift och ökad leveranskapacitet.

På uppdrag av Sandviken Energi så har denna utredning gjorts med syftet att påvisa hur mätvärden kan användas till mer än debitering och framförallt hur mätvärden kan användas för att identifiera anläggningar som påverkar returtemparaturen negativt.

Anläggningar har identifierats beroende av returtemperatur, avkylning och storlek. Dessa faktorer har valts för att bäst identifiera de anläggningar som påverkar kollektivets returtemperatur på negativast sätt.

En granskning har gjorts av de fem värst anläggningarna för att få en uppfattning om vilken typ av anläggningar som påverkar returtemperaturen negativt. Ytterligare en analys har sedan gjorts där en sänkning av returtemperaturen på 10˚C beräknas på de 50 första identifierade anläggningarna. Denna sänkning innebär att kollektivets returtemperatur sänks med ungefär 2,4˚C.

En LAVA-kalkyl har sedan använts för att beräkna hur denna sänkning på 2,4˚C påverkar produktionen och distributionen av fjärrvärme i Sandviken. Resultatet blir en vinst med 1 498 754 kr/år vilket ger ett investeringspotential på ungefär 11 miljoner kronor.

En rad åtgärdsförslag som kan användas för att genomföra en sänkning av returtemperaturen på kundernas anläggningar presenteras.

Abstract [en]

Sandviken Energi produces around 220 GWh district heating and 20 GWh electricity every year at their production facility in Björksätra Sandviken. To make this production more efficient one of the best solutions is a lowering of the return temperature.

A lowering of the return temperature means a more efficient flue-gas condensation, less heat loss to ground, lowered pump activity and increased delivery capacity.

On behalf of Sandviken Energi this investigation has been seen through with the purpose of demonstrating how measured values can be used for more than billing and foremost how measured values can be used to identify facilities that negatively affect the return temperature.

Facilities have been identified based on their return temperature, cooling, and size. These factors have been chosen to best identify the facilities that affect the collective return temperature in the most negative way.

A study has been done of the five worst facilities to get an idea of what kind of facility that negatively affects the return temperature. Another analysis was then done where a lowering of the return temperature by 10˚C was calculated on the first 50 facilities identified. This drop resulted in a lowered collective return temperature by 2,4˚C.

A LAVA-calculation was then used to calculate how this lowering of 2,4 ˚C affects the production and distribution of district heat in Sandviken. The result was an increased profit of 1 498 754 kr/year which gives an investment potential of about 11 million Swedish kronor.

A set of proposed measures that can be used to lower the return temperature of the customer’s facility is presented.

sted, utgiver, år, opplag, sider
2014. , s. 28
Emneord [sv]
Fjärrvärme, Returtemperatur, Effektivisering
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-17036OAI: oai:DiVA.org:hig-17036DiVA, id: diva2:726728
Veileder
Examiner
Tilgjengelig fra: 2014-06-30 Laget: 2014-06-18 Sist oppdatert: 2014-06-30bibliografisk kontrollert

Open Access i DiVA

Sänkning av returtemperatur(803 kB)1936 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 803 kBChecksum SHA-512
b82dddb53d7ed6b7d82e4e3f01d69e4c68ddec69de893534f51a33aa130d19af3809a863d4498767a4d7f96e83e3de3f58b63b377341a0b9d87484657310310c
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1939 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 840 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf