Cold tap water usage for a chilling system
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik.
2014 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

Both the increasing demand for comfort levels and growth in population are facts that assure that the energy demand in buildings will keep growing in the future. Heating, ventilation and air conditioning systems (HVAC systems) are the principal users of this total energy demand, where percentages over 50% have been reached. Air conditioning is essential to maintain the thermal comfort inside the buildings, and for this reason, innovative cooling systems should be analysed in order to reduce and improve energy usage of these systems.

 

The aim of this thesis is to explore the viability and limitations of a new chilling system that uses tap water as a cooling source. The project has been focused on a building owned by an insurance company in Gävle, where a cooling system has been designed to satisfy the cooling need for an extremely hot day in summer. Water is taken from the main pipe and, via a heat exchanger, it absorbs heat from the chilling circuit. The destination of the tap water, once has been used, has been discussed proposing 3 different options: deliver it to the waste, bring it back to the tap water network and reuse it for hot tap water. Later, based on the results, an overview of the system has been done pointing out the weak and strong parts.

 

When implementing this new system it has to be taken into account that cooling capacity is limited and extra requisites and limitations have to be accomplished since drinking water is used. The most energy efficient design is reusing the water for hot tap water use, since less heat will be needed to warm it up. However, if water is wanted to be reused it should not exceed 15  in order to avoid an environment where legionella could grow and become a health human threat.

A suitable situation for this system would be for building which needs cooling and has a high hot tap water demand. 

sted, utgiver, år, opplag, sider
2014.
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-17415OAI: oai:DiVA.org:hig-17415DiVA, id: diva2:740750
Veileder
Examiner
Tilgjengelig fra: 2014-08-26 Laget: 2014-08-26 Sist oppdatert: 2014-08-26bibliografisk kontrollert

Open Access i DiVA

fulltext(13606 kB)693 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 13606 kBChecksum SHA-512
0645a531f77a9797fe25a68ffb6936f112f3e45514bde54aeaea7f59db6ce81d7c4bf2b3a2bb5634e9091b27d09f8a18eb65080d6e83eddc3148dcdb5e67faa7
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 693 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 453 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf