hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Performance evaluation of contaminant removal and air quality control for local ventilation systems using the ventilation index Net Escape Velocity
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
2014 (engelsk)Inngår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 79, s. 78-89Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A concept of ventilation efficiency, Net Escape Velocity (NEV), developed by authors presents the net and integrated velocity of contaminant transport by convection and diffusion effect at a point within the room. The NEV is the effective ventilation rate with a velocity scale determining the contaminant concentration at a target point and can be expressed by vector and scalar quantities. It is the most important characteristic of NEV concept. An expanded concept of NEV (NEV*), under an assumption that the inflow flux of a contaminant on the control volume is a contaminant generation, was proposed. We believe that the NEV and NEV* distributions can provide helpful information for ventilation design to control contaminants. The purpose of this study was to demonstrate the advantage and contribution of NEV* to current ventilation design procedure by using numerical analysis. Here, it was evaluated by the NEV* that the contaminant removal performances of local ventilation systems which are a kitchen exhaust hood in a kitchen environment, a push-pull hood in an industrial environment and an adsorptive building material in a test chamber. The distributions of the NEV* as vector quantities under the different flow and diffusion fields were analyzed to investigate contaminant leakage across the hypothetical boundaries of the control target domain of the local ventilation hood and to investigate the contaminant concentration reduction performance of the adsorptive building materials. 

sted, utgiver, år, opplag, sider
2014. Vol. 79, s. 78-89
Emneord [en]
Ventilation effectiveness, Net Escape Velocity, Effective velocity of contaminant transport, Local ventilation system, Adsorptive building material, Performance evaluation
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-18340DOI: 10.1016/j.buildenv.2014.04.020ISI: 000339696500008Scopus ID: 2-s2.0-84901316899OAI: oai:DiVA.org:hig-18340DiVA, id: diva2:770034
Tilgjengelig fra: 2014-12-09 Laget: 2014-12-09 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Sandberg, Mats

Søk i DiVA

Av forfatter/redaktør
Sandberg, Mats
Av organisasjonen
I samme tidsskrift
Building and Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 619 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf