Measuring Air Change Rates using the PFT Technique in Residential Buildings in Northern Portugal
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Ventilation och luftkvalité)
2006 (Engelska)Ingår i: Proceedings of EPIC 2006 AIVC Conference,: Lyon, France 2006, 2006, s. 161-168Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Portugal has technical recommendations and standards regarding ventilation rates in natural ventilation systems. However these ventilation rates have not been fulfilled in most residential buildings recently erected in Portugal. We believe that natural ventilation systems alone are unlikely to guarantee the recommended ventilation, and so we characterized the performance of a mixed ventilation system consisting of an air inlet through self-adjustable inlets in bedrooms and living rooms, natural exhaust in bathrooms and fan exhaust systems in kitchens. We measured ventilation conditions in a residential complex of 94 apartments in the Porto area using the passive tracer gas method, more precisely the PFT technique. The study evaluates the façade’s permeability and the respective air exchange rates per compartment using the PFT technique. Seven flats were analyzed, six of which have a mixed ventilation system (continuous exhaust system in the kitchen and natural exhaust in the bathroom). The seventh flat has a natural ventilation system, enabling the performance of the two systems to be compared. The experimental results allow, namely, the evaluation of the influence of insulation, a grid with low head loss and a static ventilator in the duct of the bathroom and the continuous exhaust ventilation in the kitchen.

Ort, förlag, år, upplaga, sidor
2006. s. 161-168
Nyckelord [en]
Ventilation, dwellings, air change rate (ACH), PFT
Identifikatorer
URN: urn:nbn:se:hig:diva-912OAI: oai:DiVA.org:hig-912DiVA, id: diva2:117574
Konferens
AIVC 27th conference, Lyon, France, 20-22 November 2006
Tillgänglig från: 2007-12-04 Skapad: 2007-12-04 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

http://www.inive.org/Ibase_Search/search-detail-airbase-001.asp?ID=17201

Personposter BETA

Stymne, Hans

Sök vidare i DiVA

Av författaren/redaktören
Stymne, Hans
Av organisationen
Ämnesavdelningen för inomhusmiljö

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 25 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf