Shielding effectiveness of energy saving windows and HPM effects on coated window panes: Measurements conducted 2014-2016 - Results and lessons learned
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för elektronik, matematik och naturvetenskap, Elektronik. Electromagnetic Engineering Lab, KTH - Royal Institute of Technology, Stockholm, Sweden. (EMI)ORCID-id: 0000-0001-5562-3182
Electromagnetic Engineering Lab, KTH - Royal Institute of Technology, Stockholm, Sweden; SAAB Aeronautics, SAAB AB, Linköping, Sweden.
SAAB Aeronautics, SAAB AB, Linköping, Sweden.
SAAB Aeronautics, SAAB AB, Linköping, Sweden.
2016 (Engelska)Ingår i: IEEE International Symposium on Electromagnetic Compatibility, 2016, s. 461-466, artikel-id 7739288Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The past few decades have shown a veritable explosion of new versions of energy-saving windows and coated window panes. In the wake of this, problems with radio communications into and from within buildings has arisen. However, this unexpected attenuation of radio signals may also be used to shield a facility from incoming intentional electromagnetic interference (IEMI). With the intention to investigate the shielding effectiveness (SE) of modern windows and window panes a two-year measurement campaign was launched mid-2014. Another, little investigated area is what happens to coated glass when irradiated by a high-power microwave (HPM) source. Shielding effectiveness has been measured for different types of energy saving windows and coated window panes both in a semi-anechoic chamber and in a reverberation chamber over the frequency range 1-18 GHz. The effects of HPM irradiation were studied by comparing SE measured before and after the pulsed 28 kV/m L-band irradiation. The main conclusion is that with the right choice of window the shielding effectiveness of a building can reach up 40-50 dB. In this paper we summarize these measurements and lessons learned from the measurement campaign.

Ort, förlag, år, upplaga, sidor
2016. s. 461-466, artikel-id 7739288
Nyckelord [en]
Anechoic chambers; Electromagnetic compatibility; Electromagnetic pulse; Energy conservation; Glass; Irradiation; Magnetic shielding; Microwaves; Radio communication; Reverberation; Shielding; Signal interference; Windows, High power microwave sources; IEMI; Intentional electromagnetic interferences; Measurement campaign; pane; Reverberation chambers; Semi-anechoic chambers; Shielding effectiveness, Electromagnetic shielding
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hig:diva-23291DOI: 10.1109/EMCEurope.2016.7739288ISI: 000392194100079Scopus ID: 2-s2.0-85001033091OAI: oai:DiVA.org:hig-23291DiVA, id: diva2:1064264
Konferens
2016 International Symposium on Electromagnetic Compatibility, EMC EUROPE, Wroclaw University of Science and Technology (WUST), Wroclaw, 5-9 September 2016, Poland
Forskningsfinansiär
Myndigheten för samhällsskydd och beredskap, MSB Post- och telestyrelsen (PTS)
Anmärkning

Forskningsfinansiärer: Fortifikationsverket (FortV) och Livsmedelsverket (SLV).

Tillgänglig från: 2017-01-12 Skapad: 2017-01-12 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Ängskog, Per

Sök vidare i DiVA

Av författaren/redaktören
Ängskog, Per
Av organisationen
Elektronik
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 29 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf