Long term ventilation variation in two naturally ventilated Stockholm dwellings
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Ventilation och Luftkvalité)
2005 (Engelska)Ingår i: Indoor Air 2005: Proceedings of the 10th International Conference in Indoor Air Quality and Climate, vol 1-5, 2005, s. 3239-3243Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Passive tracer gas measurements of ventilation were performed in a single-family house and in a flat in Stockholm during four consecutive winter seasons. Measured averages of ACH data are reported for 47 two-week periods for the two naturally ventilated dwellings. The variation of ventilation is discussed in terms of variation in the ventilation driving forces induced by inside-outside temperature differences. The detached house shows a slightly better correlation between ACH and indoor-outside temperature difference than the town flat. It is concluded that

the correlations are not good enough for predictive use for either dwelling. Therefore it does not seem possible to “normalise” ventilation measurement data, obtained during one time period with a specific weather condition, to what would be expected during a period with “normal” weather conditions. A possible reason for the lack of good correlation between ACH and natural driving forces is a highly variable influence from occupant behaviour.

Ort, förlag, år, upplaga, sidor
2005. s. 3239-3243
Nyckelord [en]
ventilation, passive tracer gas, dwellings, field measurement
Identifikatorer
URN: urn:nbn:se:hig:diva-928ISBN: 978-7-89494-830-4 (tryckt)OAI: oai:DiVA.org:hig-928DiVA, id: diva2:117590
Konferens
10th International Conference on Indoor Air Quality and Climate (Indoor Air 2005) Beijing, China, Sep 04-09, 2005
Tillgänglig från: 2007-12-04 Skapad: 2007-12-04 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Person

Stymne, Hans

Sök vidare i DiVA

Av författaren/redaktören
Stymne, Hans
Av organisationen
Ämnesavdelningen för inomhusmiljö

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 128 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf