Vertical distribution of occupant-generated particles in a room with displacement ventilation
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Luftkvalitet)ORCID-id: 0000-0002-0337-8004
2002 (Engelska)Ingår i: Indoor Air 2002: 9th international conference on indoor air quality and climate, 2002, s. 509-514Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The vertical distribution of airborne particles in a room ventilated according to the displacement principle was measured using a vertically conveyed particle counter. The supply air was absolute-filtered and the particles generated through office-like activity of people. In general, particle concentrations increased with height, indicating a displacement effect. This effect improved with ventilation rate. A threshold-size of the particles could be discerned, above which the displacement effect started declining. The measured threshold-size agreed well with calculations based on the settling velocity of the particles and the hypothetical vertical piston-flow velocity of the room air (ventilation rate divided by floor area). At the ventilation rates tested (normal to high), the threshold-size was in the range 5-10 µm. Slightly negative concentration gradients were observed for large particles at the lowest ventilation rate. Hence, if hazardous substances are known to be associated with fairly large particles, the use of displacement ventilation is questionable.

Ort, förlag, år, upplaga, sidor
2002. s. 509-514
Nyckelord [en]
Particles, Displacement ventilation, Occupant activity, Vertical concentration profile
Nationell ämneskategori
Strömningsmekanik och akustik Husbyggnad
Identifikatorer
URN: urn:nbn:se:hig:diva-2728OAI: oai:DiVA.org:hig-2728DiVA, id: diva2:119390
Konferens
Indoor Air 2002, June 30 - July 5, 2002, Monterey, California
Tillgänglig från: 2007-10-15 Skapad: 2007-10-15 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Personposter BETA

Mattsson, Magnus

Sök vidare i DiVA

Av författaren/redaktören
Mattsson, Magnus
Av organisationen
Ämnesavdelningen för inomhusmiljö
Strömningsmekanik och akustikHusbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1161 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf