Mixing and displacement ventilation compared in classrooms; distribution of particles, cat allergen and CO2
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö. (Luftkvalitet)ORCID-id: 0000-0002-0337-8004
Visa övriga samt affilieringar
2003 (Engelska)Ingår i: Proceedings from Healthy Buildings 2003: 7th International conference, 2003, s. 458-464Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Mixing ventilation and displacement ventilation were compared in an intervention study in classrooms. Particles, cat allergen and CO2, were measured in classroom air at different levels above the floor, during regular lessons. With mixing ventilation, the particle concentration tended to decrease with height, with a stronger gradient occurring for larger particles. With displacement ventilation, the particle concentration increased with height, except for particles >25 µm. The displacement system thus tended to have a slight upward displacement effect on most of the particles. Significant correlations were found between concentrations of cat allergen and particles in the size fraction 1–10 µm. The particle and cat allergen concentration at breathing height did not, however, differ significantly between the two ventilation systems. CO2 was about 10% lower with displacement ventilation. A fairly high level of physical activity of the pupils is believed to have had significant dispersing effect on the airborne contaminants.

Ort, förlag, år, upplaga, sidor
2003. s. 458-464
Nyckelord [en]
Mixing ventilation, Displacement ventilation, Particles, Cat allergen, Schools, Classrooms, Air quality, Ventilation
Nationell ämneskategori
Husbyggnad Strömningsmekanik och akustik Annan industriell bioteknik
Identifikatorer
URN: urn:nbn:se:hig:diva-2729OAI: oai:DiVA.org:hig-2729DiVA, id: diva2:119391
Konferens
Healthy Buildings 7th International Conference Energy-Efficient Healthy Buildings. Singapore, 7th to 11th December 2003
Tillgänglig från: 2007-10-15 Skapad: 2007-10-15 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Personposter BETA

Mattsson, Magnus

Sök vidare i DiVA

Av författaren/redaktören
Mattsson, Magnus
Av organisationen
Ämnesavdelningen för inomhusmiljö
HusbyggnadStrömningsmekanik och akustikAnnan industriell bioteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1189 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf