hig.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Energisimulering i modulhus: Fallstudie för uppskattning av energiprestanda och därefter energieffektivisera enligt passivhusstandaren
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för byggnadsteknik, energisystem och miljövetenskap.
2019 (Svenska)Självständigt arbete på grundnivå (högskoleexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Abstract

The Building sector is today an important sector in our society, which means that more people move from the urban area to the big cities, which in turn increases building production. The building and service sector is the largest energy waste in Sweden and internationally, which is about 40% of Sweden's total energy use and 60% of that energy goes to heating. The EU Directive Energy Performance of Buildings Directive (EPBD), implemented the concept of near zero-energy houses, which comes into full force in 2020, which means that all newly-built buildings must be energy-efficient with better energy performance than todays buildings. This is in connection with the need of houses/buildings and rental costs continuing to increase. For this reason, Ljusbo Hyreshus AB has invented a solution that includes both climatesmart rental apartments and cheap rental costs, which has attracted more than 20 communes (kommuner in Sweden) to offer land for these apartments. The purpose of this thesis is to find out the energy performance of one of Ljusbo Hyreshus AB's prototype module houses. Furthermore, improvement proposals would be developed to make the module house more energy efficient. The prototype house consisted of a single-storey modularhouse that stay in Söderhamn, which has been chosen in this thesis for further investigations. The house had a total area of 45 m2 and consisted of 3 rooms and kitchen. In this case study, the energy performance has been developed using analysis methods in the form of hand calculations and the energy signature method. Subsequently, the result of the analysis would be validated and would form the basis for later identification of various energy efficiency measures that contributed to the reduction of energy performance in the house and thereby achieved the passive house standard. The result shows that the modularhouse does not fullfil BBR's requirements at present, because the house misses important components which is important for energy performance. For this reason, improvement proposals, specifically regarding the climate shell, on energy efficiency measures have been developed in this report. With the help of these energy efficiency measures, which mainly consist of additional insulation and energy-efficient windows and with an energy-efficient ventilation system with heat recovery (FTX) and an installed air-water heat pump, the passive house standard has been possible to achieve. Future measures, such as the installation of solar cells, have also been examined in the report. This is due to converting the building from a passive house to a plus energy house.

Ort, förlag, år, upplaga, sidor
2019. , s. 64
Nyckelord [sv]
Energisimulering, Energisignaturmetoden, Byggnaders energiprestanda, Byggnaders energianvändning
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:hig:diva-29781OAI: oai:DiVA.org:hig-29781DiVA, id: diva2:1322792
Ämne / kurs
Byggnadsteknik
Utbildningsprogram
Högskoleingenjör
Handledare
Examinatorer
Tillgänglig från: 2019-06-17 Skapad: 2019-06-11 Senast uppdaterad: 2019-06-17Bibliografiskt granskad

Open Access i DiVA

Energisimulering i modulhus(5042 kB)24 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 5042 kBChecksumma SHA-512
e79bb89598dd711f51df28d8451ebe55744d43029bb60f3f1827524f329f013c70d57f7e35ec53f5777d7107ef0e27ec63be63487a551bf1d7ffbc3860013682
Typ fulltextMimetyp application/pdf

Av organisationen
Avdelningen för byggnadsteknik, energisystem och miljövetenskap
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 24 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 41 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf