hig.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Input Dependent Integral Nonlinearity Modeling for Pipelined Analog-Digital Converters
Signal Processing Laboratory, ACCESS Linnaeus Center, Royal Institute of Technology, Stockholm, Sweden.
Signal Processing Laboratory, ACCESS Linnaeus Center, Royal Institute of Technology, Stockholm, Sweden.ORCID-id: 0000-0002-2718-0262
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för elektronik, matematik och naturvetenskap, Elektronik. (Elektronik)ORCID-id: 0000-0001-5429-7223
Signal Processing Laboratory, ACCESS Linnaeus Center, Royal Institute of Technology, Stockholm, Sweden.
2010 (Engelska)Ingår i: IEEE Transactions on Instrumentation and Measurement, ISSN 0018-9456, E-ISSN 1557-9662, Vol. 59, nr 10, s. 2609-2620Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Integral nonlinearity (INL) for pipelined analog–digital converters (ADCs) operating at RF is measured and characterized. A parametric model for the INL of pipelined ADCs is proposed, and the corresponding least-squares problem is formulated and solved. The INL is modeled both with respect to the converter output code and the frequency stimuli, which is dynamic modeling. The INL model contains a static and a dynamic part. The former comprises two 1-D terms in ADC code that are a sequence of zero-centered linear segments and a polynomial term. The 2-D dynamic part consists of a set of polynomials whose parameters are dependent on the ADC input stimuli. The INL modeling methodology is applied to simulated and experimental data from a 12-bit commercial ADC running at 210 mega samples per second. It is demonstrated that the developed methodology is an efficient way to capture the INL of nowadays ADCs running at RF, and it is believed that the methodology is powerful for INL-based ADC postcorrection in wideband applications.

Ort, förlag, år, upplaga, sidor
2010. Vol. 59, nr 10, s. 2609-2620
Nyckelord [en]
Analogdigital conversion, integral nonlinearity (INL), least-squares methods, parametric modeling, postcorrection, segmentation
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hig:diva-7438DOI: 10.1109/TIM.2010.2045551ISI: 000283263900014Scopus ID: 2-s2.0-77956774847OAI: oai:DiVA.org:hig-7438DiVA, id: diva2:347928
Tillgänglig från: 2010-09-03 Skapad: 2010-09-02 Senast uppdaterad: 2019-12-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Händel, PeterBjörsell, Niclas

Sök vidare i DiVA

Av författaren/redaktören
Händel, PeterBjörsell, Niclas
Av organisationen
Elektronik
I samma tidskrift
IEEE Transactions on Instrumentation and Measurement
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 1135 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf