hig.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental investigation and CFD analysis of cross-ventilated flow through single room detached house model
Ritsumeikan University.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik.
Osaka University.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet.
2010 (Engelska)Ingår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 45, nr 12, s. 2723-2734Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Cross-ventilation is a complicated flow problem and difficult to control because wind exhibits a large degree of variation. The paper focuses on three items: a) to clarify and understand some of the basic characteristics of airflow as the influence of the opening size on the windward vortex and the leeward wake; b) to explore what information about the flow above the ground can be retrieved from pressure measurements on the ground; and c) to explore the accuracy of CFD. To meet these objectives, wind tunnel tests and CFD analyses were carried out. The studied object was a detached-house model provided with two openings. The size of these openings was changed in a wide range from narrow cracks to large openings. In the experiments, pressure measurements on the ground and PIV measurements were made. The internal flow was visualized with the sand erosion method. Pressure measurement on a floor surface is a relatively easy and an inexpensive method. In this experiment, the windward and leeward areas in particular were investigated to understand flow pattern and to confirm correspondence between flow pattern and recorded pressure on the ground. Those measurements show the difference in flow at different size openings in terms of the vortex on the windward side and the wake. When the size of the opening exceeded a certain value the near wake on the leeward side disappeared and on the windward side the vortex disappeared. The pressure distribution, flow pattern, and velocity profile are shown and compared between measurement and CFD.

Ort, förlag, år, upplaga, sidor
2010. Vol. 45, nr 12, s. 2723-2734
Nyckelord [en]
Cross-ventilation, Wind tunnel, PlV, Pressure measurement, CFD, Reynolds stress model
Nationell ämneskategori
Energisystem
Identifikatorer
URN: urn:nbn:se:hig:diva-10264DOI: 10.1016/j.buildenv.2010.06.001ISI: 000281326800013Scopus ID: 2-s2.0-77955425539OAI: oai:DiVA.org:hig-10264DiVA, id: diva2:442580
Tillgänglig från: 2011-09-21 Skapad: 2011-09-21 Senast uppdaterad: 2018-12-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Sandberg, MatsClaesson, Leif

Sök vidare i DiVA

Av författaren/redaktören
Sandberg, MatsClaesson, Leif
Av organisationen
Byggvetenskap - installationsteknikBMG Labbet
I samma tidskrift
Building and Environment
Energisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 1171 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf