hig.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Measurement and characterization of glucose in NaCl aqueous solutions by electrochemical impedance spectroscopy
Vrije University of Brussels, Belgium.
Vrije University of Brussels, Belgium.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för elektronik, matematik och naturvetenskap, Elektronik. Vrije University of Brussels, Belgium.
Vrije University of Brussels, Belgium.
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Biomedical Signal Processing and Control, ISSN 1746-8094, Vol. 14, nr 1, s. 9-18Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Electrochemical impedance spectroscopy (EIS) allows measuring the properties of the system as a function of the frequency as well as distinguishing between processes that could be involved: resistance, reactance, relaxation times, amplitudes, etc. Although it is possible to find related literature to in vitro and in vivo experiments to estimate glucose concentration, no clear information regarding the condition and precision of the measurements are easily available. This article first address the problem of the condition and precision of the measurements, as well as the effect of the glucose over the impedance spectra at some physiological (normal and pathological) levels. The significance of the measurements and the glucose effect over the impedance are assessment regarding the noise level of the system, the experimental error and the effect of using different sensors. Once the data measurements are analyzed the problem of the glucose estimation is addressed. A rational parametric model in the Laplace domain is proposed to track the glucose concentration. The electrochemical spectrum is measured employing odd random phase multisine excitation signals. This type of signals provides short acquisition time, broadband measurements and allows identifying the best linear approximation of the impedance as well as estimating the level of noise and non-linearities present in the system. All the experiments were repeated five times employing three different sensors from the same brand in order to estimate the significance of the experimental error, the effects of the sensors and the effect of the glucose over the impedance. 

Ort, förlag, år, upplaga, sidor
2014. Vol. 14, nr 1, s. 9-18
Nyckelord [en]
Best linear approximation, Electrochemical impedance spectroscopy, Glucose sensor, Modeling, Nonparametric model, Odd random phase multisine, Parametric model, Rational model, Experiments, Glucose sensors, Models, Sensors, Signal processing, Spectroscopy, Best linear approximations, Multisine, Non-parametric model, Parametric modeling, Rational models, Glucose, sodium chloride, accuracy, aqueous solution, article, excitation, experiment, impedance, in vitro study, noise, priority journal, sensor
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hig:diva-18458DOI: 10.1016/j.bspc.2014.06.007ISI: 000347019500002Scopus ID: 2-s2.0-84904557766OAI: oai:DiVA.org:hig-18458DiVA, id: diva2:770216
Tillgänglig från: 2014-12-10 Skapad: 2014-12-10 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Van Moer, Wendy

Sök vidare i DiVA

Av författaren/redaktören
Van Moer, Wendy
Av organisationen
Elektronik
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 209 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf