hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Predicted Percentage Dissatisfied with Ankle Draft
Center for the Built Environment, University of California, Berkeley, CA, USA.ORCID-id: 0000-0002-0642-9700
Center for the Built Environment, University of California, Berkeley, CA, USA.ORCID-id: 0000-0003-1285-5682
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.ORCID-id: 0000-0002-2171-3013
Department of Civil and Environmental Engineering, University of California, Berkeley, CA, USA.ORCID-id: 0000-0001-5645-3357
2017 (engelsk)Inngår i: Indoor Air, ISSN 0905-6947, E-ISSN 1600-0668, Vol. 27, nr 4, s. 852-862Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Draft is unwanted local convective cooling. The draft risk model of Fanger et al. (Energy and Buildings 12, 21-39, 1988) estimates the percentage of people dissatisfied with air movement due to overcooling at the neck. There is no model for predicting draft at ankles, which is more relevant to stratified air distribution systems such as underfloor air distribution (UFAD) and displacement ventilation (DV). We developed a model for predicted percentage dissatisfied with ankle draft (PPDAD ) based on laboratory experiments with 110 college students. We assessed the effect on ankle draft of various combinations of air speed (nominal range: 0.1-0.6 m/s), temperature (nominal range: 16.5-22.5 °C), turbulence intensity (at ankles), sex, and clothing insulation (< 0.7 clo; lower legs uncovered and covered). The results show that whole body thermal sensation and air speed at ankles are the dominant parameters affecting draft. The seated subjects accepted a vertical temperature difference of up to 8 °C between ankles (0.1 m) and head (1.1 m) at neutral whole body thermal sensation, 5 °C more than the maximum difference recommended in existing standards. The developed ankle draft model can be implemented in thermal comfort and air diffuser testing standards.

sted, utgiver, år, opplag, sider
2017. Vol. 27, nr 4, s. 852-862
Emneord [en]
displacement ventilation; draft risk model; local thermal discomfort; thermal comfort; thermal stratification; underfloor air distribution
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-23266DOI: 10.1111/ina.12364ISI: 000403895400014PubMedID: 28005297Scopus ID: 2-s2.0-85010781747OAI: oai:DiVA.org:hig-23266DiVA, id: diva2:1063601
Merknad

Funding Agency:

Republic of Singapore's National Research Foundation

Tilgjengelig fra: 2017-01-10 Laget: 2017-01-10 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Liu, ShichaoSchiavon, StefanoKabanshi, AlanNazaroff, William W

Søk i DiVA

Av forfatter/redaktør
Liu, ShichaoSchiavon, StefanoKabanshi, AlanNazaroff, William W
Av organisasjonen
I samme tidsskrift
Indoor Air

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 66 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf