Lönsamheten för energiåtervinning i ventilation Kv. Bordsgossen: Undersökning kring lönsamheten av att installera energiåtervinning i ett 60-tals flerbostadshus
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem.
2017 (svensk)Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
Hållbar utveckling
Uppsatsen/examensarbetet handlar till övervägande del om hållbar utveckling enligt högskolans kriterier
Abstract [sv]

Sedan oljekrisen på 1970-talet har västvärlden strävat efter att hitta energieffektiva     metoder för uppvärmning i fastigheter. I EU står bostadssektorn för ca 40% av det totala energibehovet och den enskilt största delen i människans ekologiska fotavtryck är koldioxidutsläpp, främst via förbränning av fossila bränslen där energisektorn historiskt stått för en stor del av dess utsläpp. Oljan har som uppvärmningsmedel så gott som fasats ut och på ventilationssidan har det de senaste 30 åren hänt fantastiskt mycket där man hela tiden strävar efter att hitta effektivare och miljömässigt hållbara system. Man har så gott som helt lyckats att få bort fossila bränslen som uppvärmningskälla från bostadssektorn och på ventilationssidan har man kommit så långt att man till och med börjar återgå från stora komplexa system till de något enklare systemen som man lyckats optimera  bl.a frånluftsvärmepumpar. Just frånluftsvärmepumpar spås en fortsatt god framtid där effektiviteten på pumparna, det så kallade COP-värdet (coefficient of performance) tros kunna fördubblas.

Kv. Bordsgossen är ett flerfamiljsbostadshus i centrala Gävle och består av fem huskroppar fördelade på 53 lägenheter och därutöver kontors- och butikslokaler på bottenplan. Fastigheten som är från 1963 saknar helt energiåtervinning och fastighetsägaren Svedinger Fastigheter vill nu ändra på detta. Denna rapport tar vid där en tidigare energikartläggning slutar och i denna rapport har det undersökts om det finns lönsamhet i frånluftsvärmepump för fastighetens lägenheter, samt lönsamheten i värmeväxlare för fastighetens garage och en värmeväxlare för den butikslokal som inhyser företaget Arkitektkopia. Resultatet visar att det vid uppskattad installationskostnad finns god ekonomi i att installera frånluftsvärmepump i fastigheten samt att installera värmeväxlare för den lokal som inhyser Arkitektkopia och för fastighetens garage. Det som fastighetsägaren måste ta hänsyn till är att den uppskattade installationskostnaden nödvändigtvis inte är korrekt, utan bör ses som en fingervisare. Svedinger Fastigheter bör även hålla ett öga på den eventuella flödestaxa som den lokala fjärrvärmedistributören funderar på att tillämpa, som om den tas i anspråk antas kunna ha stor påverkan på den ekonomiska vinning som finns att hämta i energieffektivisering. Vidare behöver ventilationen i fastigheten injusteras och om fastighetsägaren beslutar att skrida till verket med ett fönsterbyte ska man ha klart för sig att det kommer att påverka fastighetens termiska komfort och energibehov.

Abstract [en]

Since the oil crisis in the 1970’s the western world has sought to find energy-efficient methods for heating in real estate. In the EU, the housing sector accounts for about 40% of the total energy demand, and the single largest part of man's ecological footprint is carbon dioxide emissions, primarily through the use of fossil fuels in which the energy sector has historically accounted for a large part of its emissions. Oil has in the terms of heating almost entirely been phased out and over the last 30 years the ventilations development has seen a great deal of progress where the market constantly strives for better efficiency and environmentally friendly techniques. The industry has managed to almost at full extent to remove fossil fuels as a source of heating for housing. On the ventilation side, the technique has come so far that systems start returning from large complex systems to the simpler systems that is optimized, for example, exhaust air heat pumps (EHAP). Exhaust air heat pumps are expected have a good future ahead where the efficiency of the pumps, the so-called COP-value (coefficient of performance), is predicted to be doubled. 

Kv. Bordsgossen is a multi-family house in central part of the city of Gävle and consists of five houses divided into 53 apartments and on the ground floor consists of offices and retail premises. The property, which dates back to 1963, has no energy recovery and the property owner, Svedinger Fastigheter wants to change this.  This report has investigated whether there is profitability for a exhaust air heat pump in the property's apartments, as well as the profitability of heat exchanger for the property's garage as well as for the premises that accommodate the company Arkitektkopia. The result shows that, at the estimated installation cost, there is a good economy in installing exhaust air heat pump in the property as well as installing heat exchanger in the part  inhabited by Arkitektkopia, and in the facilities garage. What the property owner needs to take into consideration is that the estimated installation costs necessarily isn’t correct, but should be considered  as a direction point. Svedinger Fastigheter also needs to keep an eye on the possible flow rate that the local district heating distributor is considering applying. Should it be applied it is predicted to have a huge impact on the economical earnings in energy efficient technology. Furthermore, the ventilation is in needs of a adjustment and if the property owner decides to move on  with a window change it will affect the property's thermal comfort and energy needs.

sted, utgiver, år, opplag, sider
2017. , s. 76
Serie
Robin Säker
Emneord [en]
Ventilation, Heat pump, Heat exchanger, Energy-efficiency
Emneord [sv]
Ventilation, Frånluftsvärmepump, Värmeväxlare, Energieffektivisering, Energianvändning
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-24045OAI: oai:DiVA.org:hig-24045DiVA, id: diva2:1104883
Fag / kurs
Energy systems
Utdanningsprogram
Högskoleingenjör
Veileder
Examiner
Tilgjengelig fra: 2017-06-15 Laget: 2017-06-02 Sist oppdatert: 2017-06-15bibliografisk kontrollert

Open Access i DiVA

fulltext(20745 kB)226 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 20745 kBChecksum SHA-512
af7aa2fc09d377de787100bb8afc4d40556718a3c7de71faaed4a23782e63e64e486e102c1f894f4dead0d5766565fc43d6720bd73a1ae8be768016106665702
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 226 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 242 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf