Effects of intermittent air velocity on thermal and draught perception during transient temperature conditions
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
2008 (engelsk)Inngår i: The International Journal of Ventilation, ISSN 1473-3315, E-ISSN 2044-4044, Vol. 7, nr 1, s. 59-66Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Previous research has shown that air movement has a significant influence on humans' thermal comfort. For persons feeling cool, air movement tends to be perceived as draught, whilst when feeling warm air movements may provide a desired cooling effect. In the transition zone it therefore seems difficult to use constant air velocity as a tool for cooling without creating draught problems. Nevertheless, from an energy saving perspective it appears to be far more efficient to use enhanced convective cooling, induced by the air movement, to cool only the occupants instead of the entire building. One possible way to use air movement as a method to improve thermal comfort without resultant draught problems could be to use intermittent air velocity instead of constant velocity. The present paper reports results from three experiments where subjects have been exposed to velocity variations, showing support for the hypothesis that it is possible to cool humans and reduce the percentage of occupants who are dissatisfied with the room temperature, without creating draught problems, through intermittent cooling.

sted, utgiver, år, opplag, sider
2008. Vol. 7, nr 1, s. 59-66
Emneord [en]
Convective cooling; Draught perception; Human cooling; Intermittent air movement; Thermal comfort; Velocity variations
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-1680DOI: 10.1080/14733315.2008.11683799ISI: 000207586500006Scopus ID: 2-s2.0-45749143602OAI: oai:DiVA.org:hig-1680DiVA, id: diva2:118342
Tilgjengelig fra: 2008-06-09 Laget: 2008-06-09 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Wigö, Hans

Søk i DiVA

Av forfatter/redaktør
Wigö, Hans
Av organisasjonen
I samme tidsskrift
The International Journal of Ventilation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 84 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf