hig.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The effects of inverting prisms on the horizontal-vertical illusion: a systematic effect of downward gaze
Högskolan i Gävle, Centrum för belastningsskadeforskning. Högskolan i Gävle, Institutionen för pedagogik, didaktik och psykologi, Ämnesavdelningen för folkhälsovetenskap. Department of Optometry and Optical Science, Faculty of Physics and Mathematics, University of Latvia, Riga, Latvia.
Department of Optometry and Optical Science, Faculty of Physics and Mathematics, University of Latvia, Riga, Latvia.
Högskolan i Gävle, Centrum för belastningsskadeforskning.
2007 (Engelska)Ingår i: Experimental Brain Research, ISSN 0014-4819, E-ISSN 1432-1106, Vol. 183, nr 1, s. 9-15Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The purpose of this work is to compare the relative contributions from the extraocular and sensory systems on the magnitude of the horizontal-vertical illusion (HVI). The visual HVI refers to the general tendency to overestimate vertical extensions of small-scale lines on a picture plane relative to the horizontal by 4-16% depending on the method of measurement. The HVI line stimuli consisted of luminous vertical and horizontal lines forming "L-profiles" located in the frontoparallel plane at a 45 cm viewing distance, collinearly with a binocular gaze. The home position of gaze was aligned to the center of the screen with the ear-eye angle concordant with the environmental horizontal. Illusion strength was quantified when subjects fixated the HVI line stimuli in four quadrants of the visual field. The HVI was also viewed through prism lenses that inverted the retinal images by 180 degrees , thereby dissociating the sensory "up-down" direction from the oculomotor up-down frame of reference. The results revealed a systematically lower magnitude of the HVI in the bottom visual field regardless of whether subjects fixated the HVI with the distorting prisms or without. Taken together, these results suggest that the HVI is sensitive to small-angle gaze shifts. In agreement with several recent findings, these results are interpreted as implying that the brain imposes an enhanced analytic structure on the ascending sensory information during downward gaze.

Ort, förlag, år, upplaga, sidor
2007. Vol. 183, nr 1, s. 9-15
Nyckelord [en]
Gaze; Horizontal vertical illusion; Prisms; Sensorimotor; Visual space
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
URN: urn:nbn:se:hig:diva-2878DOI: 10.1007/s00221-007-1015-zISI: 000249623500002PubMedID: 17609882Scopus ID: 2-s2.0-34648832287OAI: oai:DiVA.org:hig-2878DiVA, id: diva2:119540
Tillgänglig från: 2007-11-28 Skapad: 2007-11-28 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Richter, Hans O.

Sök vidare i DiVA

Av författaren/redaktören
Richter, Hans O.
Av organisationen
Centrum för belastningsskadeforskningÄmnesavdelningen för folkhälsovetenskap
I samma tidskrift
Experimental Brain Research
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 1112 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf