hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Draught free intermittent cooling at moderate over temperatures by generating pulses of high velocities.
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
Högskolan i Gävle, Institutionen för teknik och byggd miljö, Ämnesavdelningen för inomhusmiljö.
2005 (engelsk)Inngår i: Proceedings of 10th International Conference on Indoor Air Quality and Climate, 2005, s. 209-213Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Schools in Scandinavia are buildings where there is a need of cooling only for a short period of time. Due to the large number of students the ventilation system often cannot provide the necessary cooling without causing draught. We introduce additional cooling by an internal high velocity system that cool people. This system creates a downward air stream of five minutes duration that blows the rising thermal plume above a person away, thus exposing the student to an enhanced convective cooling. As the heat load was high the occupants were at the same time exposed to a rising room temperature. Assessments have been made where groups of subjects were exposed to velocity variations respectively constant low velocity. The mean thermal votes and air quality were measured during 80 minutes. The results are analysed as differences between the two groups in change over time.

sted, utgiver, år, opplag, sider
2005. s. 209-213
Emneord [en]
thermal comfort, intermittent cooling, internal high velocity system, high velocity pulse
Identifikatorer
URN: urn:nbn:se:hig:diva-2963DOI: 10.1111/j.1600-0668.2005.00002.xOAI: oai:DiVA.org:hig-2963DiVA, id: diva2:119625
Konferanse
10th International Conference on Indoor Air Quality and Climate, 4-9 September 2005, Beijing, China
Tilgjengelig fra: 2007-11-28 Laget: 2007-11-28 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Wigö, HansSandberg, Mats

Søk i DiVA

Av forfatter/redaktør
Wigö, HansSandberg, Mats
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 386 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf