Fjärrvärmesystem
University of Gävle, Department of Technology and Built Environment, Ämnesavdelningen för energi- och maskinteknik.
2008 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

This is a report written for an examination project C-level, on the subject of energy. The examination project is a product of the FVB Sweden AB (district heating bureau). It started with a meeting with Stefan Jonsson FVB Sweden AB, were he explained the content of the project, and from this a presentation of the problem was made. The problem that needed to be solved was how they could control the valves in the system to provide heating to everyone in the system. The valves are often oversized so the pump in the heating plant would have to be enormous to be able to provide enough flow to be sufficient, if everyone in the system had there valves fully opened.

 

I came up with two solutions to the problem, one was a wireless network that could keep track of the valves and the other solution was an extra sensor that was placed on the radiator. The purpose for that was to open the valve if the temperature dropped more than one degree inside. With the help of a program called IDA it was calculated that, if the temperature drop five degrees, they would have sixteen hours at the heating power plant to open the flow before the sensor open the valves.

 

After careful consideration I came up with the conclusion that the wireless network must be the best solution. Mostly because you can monitor all the clients in the system from the heating power plant and that will make it easier to discover faults and temperature differences.

Wireless networks is already a well tested solution in form of wireless controlled electricity meters so it shouldn’t be to much of a problem connecting these sensors to it either.

Place, publisher, year, edition, pages
2008. , p. 49
Keywords [sv]
Fjärrvärme, energi
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-4484Archive number: TEX 080530OAI: oai:DiVA.org:hig-4484DiVA, id: diva2:219020
Presentation
(English)
Uppsok
teknik
Supervisors
Examiners
Available from: 2009-06-04 Created: 2009-05-25 Last updated: 2009-06-04Bibliographically approved

Open Access in DiVA

fulltext(845 kB)920 downloads
File information
File name FULLTEXT01.pdfFile size 845 kBChecksum SHA-512
4e44b7a91ad0d63eeffb583e6a6b176e3eaa44d4482c5b929e718a6001c1e0a82868d1f0404cd5c7843a79639684c562f5a015cf77b565ca75a028b002b12a00
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Holmström, Susanne
By organisation
Ämnesavdelningen för energi- och maskinteknik
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 920 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 336 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf