hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Wind tunnel measurements of pressure distribution on  the facade of a church
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. (Indoor environment)
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. (Indoor environment)ORCID-id: 0000-0002-0337-8004
University of Nottingham, UK. (Department of Architecture and Built Environment)
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, BMG Labbet.
2011 (engelsk)Inngår i: Proc. EEHB 2011: Conference on Energy Efficiency in Historic Buildings / [ed] Tor Broström & Lisa Nilsen, Visby: Gotland University Press, 2011Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Elderly churches have a unique shape with their high towers and long naves. There seems to be few if any reported measurement of pressure distribution on churches. Churches are naturally ventilated buildings and therefore when the wind speed is high  the  wind becomes an important driving force for ventilation. A model in scale 1: 200 was built of a 19th century Swedish church provided with a crawl space.The pressure on the façade of the model was recorded in 42 points. With the aim of studying the ventilation of the church, dedicated measuring points were located on windows, doors and in the positions corresponding to the location of the openings in the crawl space.  Some field trials were undertaken with the scope of measuring the time history of the static pressure on the façade in some positions corresponding to measuring points on the wind tunnel model. Examples of these measurements are  reported in the paper. With the aim of measuring the “region of influence” on the ground caused by the church, also the static pressure on the ground was recorded in the wind tunnel tests.  The static pressure on ground was recorded with a pressure plate provided with 400 pressure taps arranged in a quadratic pattern.

sted, utgiver, år, opplag, sider
Visby: Gotland University Press, 2011.
Emneord [en]
Wind pressure coefficient, Building surface, Wind tunnel, Church, Air infiltration
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-9258ISBN: 978-91-86343-11-8 (tryckt)OAI: oai:DiVA.org:hig-9258DiVA, id: diva2:416839
Konferanse
EEHB 2011: Conference on Energy Efficiency in Historic Buildings. Visby. Sweden.
Prosjekter
Church projectTilgjengelig fra: 2011-05-13 Laget: 2011-05-13 Sist oppdatert: 2018-12-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Sandberg, MatsMattsson, MagnusClaesson, Leif

Søk i DiVA

Av forfatter/redaktør
Sandberg, MatsMattsson, MagnusClaesson, Leif
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 469 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf