Development of instruments for assessment of knowledge and skills in performing venepuncture and inserting peripheral venous catheters
Karolinska institutet.
Högskolan i Gävle, Akademin för hälsa och arbetsliv, Avdelningen för hälso- och vårdvetenskap, Vårdvetenskap.
Karolinska instituet.
Karolinska Instituet.
2013 (engelsk)Inngår i: Journal of Vascular Access, ISSN 1129-7298, E-ISSN 1724-6032, Vol. 14, nr 4, s. 364-372Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: Performing venepuncture is one of the most routinely performed invasive procedures in nursing care. The aim of this study was to develop instruments for the assessment of nursing students' knowledge and skills when performing venepuncture and inserting a peripheral venous catheter. 
Methods: Two instruments were developed using the following steps. 1) Assessment items of importance for the procedures (venepuncture 48 items and peripheral venous catheter 51 items) were collected from focus groups including nurses, lecturers and patients. 2) The number of items was reduced using a method based on the Delphi method. Experts (n=51) reviewed the instruments in two rounds. The revised versions included 31 items for venepuncture and 33 items for peripheral venous catheter insertion. 3) Usability tests were conducted by nurses who tested the instruments to confirm that items were possible to assess. 4) Inter-rater reliability was assessed by twelve lecturers who in pairs, but independently of each other, used the instruments to assess 50 nursing students. 
Results: Proportion of agreement and Cohen's kappa coefficient were calculated for each item to determine inter-rater reliability. Among the tested items for both instruments, the median proportion of agreement was 1 (range 0.66-1) and the median kappa was 0.52 (range 0.22-1). 
Conclusions: The instruments developed for assessing nursing students' knowledge and skills of venepuncture and peripheral venous catheter insertion showed satisfactory inter-rater reliability.

sted, utgiver, år, opplag, sider
2013. Vol. 14, nr 4, s. 364-372
Emneord [en]
Assessment; Instrument; Knowledge; Nursing education; Skill
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-15226DOI: 10.5301/jva.5000147ISI: 000329565700010Scopus ID: 2-s2.0-84889673244OAI: oai:DiVA.org:hig-15226DiVA, id: diva2:648019
Tilgjengelig fra: 2013-09-13 Laget: 2013-09-13 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopusFulltextFulltext

Person

Löfmark, Anna

Søk i DiVA

Av forfatter/redaktør
Löfmark, Anna
Av organisasjonen
I samme tidsskrift
Journal of Vascular Access

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 372 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf