Effects of intermittent air velocity on thermal and draught perception: A field study in a school environment
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Byggvetenskap - installationsteknik. (Inomhusmiljö)
2013 (engelsk)Inngår i: The International Journal of Ventilation, ISSN 1473-3315, E-ISSN 2044-4044, Vol. 12, nr 3, s. 249-255Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Air movement in an indoor space may be experienced in very different ways. For persons feeling cool, air movement tends to be perceived as draught, whilst when feeling warm air movement may provide a desired cooling effect. In the transition zone it therefore seems difficult to use constant air velocity as a tool for cooling without creating draught problems. One possible way to use air movement as a method to improve thermal comfort, without resultant draught problems, could be to use intermittent air velocity instead of constant velocity. This new cooling method was implemented in a high school in Sweden and evaluated during spring (April) and autumn (September). The present paper reports results from two field experiments where subjects were exposed to velocity variations. The analysis shows significant effects of velocity condition on thermal comfort and air quality. In summary, people exposed to velocity variation perceived the air as cooler and fresher compared with those exposed to constant low velocity and very few classified the air movement as draught. A further conclusion is that even the pupils who were exposed to velocity variation wanted slightly more air movement.

sted, utgiver, år, opplag, sider
2013. Vol. 12, nr 3, s. 249-255
Emneord [en]
thermal comfort, intermittent air movement, draught perception, velocity variations, convective cooling
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-15768ISI: 000329606000005Scopus ID: 2-s2.0-84892729894OAI: oai:DiVA.org:hig-15768DiVA, id: diva2:665359
Tilgjengelig fra: 2013-11-19 Laget: 2013-11-19 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Scopushttp://ijovent.org/doi/abs/10.5555/2044-4044-12.3.249

Personposter BETA

Wigö, Hans

Søk i DiVA

Av forfatter/redaktør
Wigö, Hans
Av organisasjonen
I samme tidsskrift
The International Journal of Ventilation

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 105 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf