Numerical analysis and parametric study of the thermal behavior in multiple-skin facades
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 67, s. 44-55Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The general aim of this research is contributed to the energy performance assessment of single storey multiple-skin facade. To cover this aim; multiple skin facade are studied by means of experiments and numerical simulation. In this research a numerical model for multiple-skin facades with mechanical and natural ventilation has been developed. The numerical model is two-dimensional and based on a cell centered volume method (CVM). As an improvement, radiation and convection are treated separately and by this means an innovative method is applied to calculate the view factors and heat transfer coefficients between surfaces and each cavity. Then the developed numerical model is validated using measurements from the vliet test building. However, there is no multiple-skin facade application in Tehran. Thus the model is used to assess the influence of different multiple-skin facade parameters in Tehran's climate conditions to show its effect on heat losses if this technology would be applied. As a consequence of the diversity of results, designer should be aware that multiple-skin facades do not necessarily improve the energy efficiency of their designs. (C) 2013 Elsevier B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
2013. Vol. 67, s. 44-55
Nyckelord [en]
Air flow window, Double skin facades, Numerical simulation, Sensitive analyses, Parametric study
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:hig:diva-17817DOI: 10.1016/j.enbuild.2013.08.014ISI: 000328094000005Scopus ID: 2-s2.0-84883688615OAI: oai:DiVA.org:hig-17817DiVA, id: diva2:761825
Tillgänglig från: 2014-11-08 Skapad: 2014-11-08 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Ghahremanian, Shahriar

Sök vidare i DiVA

Av författaren/redaktören
Ghahremanian, Shahriar
Av organisationen
Energiteknik
I samma tidskrift
Energy and Buildings
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 87 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf