Air infiltration into naturally ventilated apartments in multifamily dwellings
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Miljöteknik.ORCID-id: 0000-0002-8985-2562
Building Services LTH, Lund University, Lund, Sweden .
Building Physics LTH, Lund University, Lund, Sweden.
Building Services LTH, Lund University, Lund, Sweden .
2014 (Engelska)Ingår i: Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate, 2014, s. 34-40Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

This study presents the ACH for ten apartments in naturally ventilated multifamily dwellings for two cases inlet vent manipulations: i) fully opened inlet vents; and ii) fully closed and taped inlet vents. Even with fully opened inlet vents the resulting ventilation is rather poor. The average ACH is 0.26±0.16 h-1. All apartments fall in the lower quartile in terms of ACH when compared to other multifamily dwellings in Sweden. A method using two different tracers A and B is presented that allow for measurement of the partial flow from the stairway zone and the partial flow from other pathways into the apartment. On the average 10-20% of the airflow into a typical apartment in a naturally ventilated multifamily dwelling seems to originate from the stairway zone when the inlet vents are fully opened. By closing and taping the inlet vents, the airtightness of the apartments have been investigated. The average direct leakage flow, i.e. not from the stairway zone, is 17 m3/h but the variation is large. Layout B seems to leak the most, followed by A and then C.

Ort, förlag, år, upplaga, sidor
2014. s. 34-40
Nyckelord [en]
Air infiltration rate, Air leakage, Multizone building, Natural ventilation, PFT tracer gas, Air quality, Apartment houses, Buildings, Housing, Indoor air pollution, Leakage (fluid), Vents, Air infiltration, Multizone, Tracer gas, Ventilation
Nationell ämneskategori
Strömningsmekanik och akustik
Identifikatorer
URN: urn:nbn:se:hig:diva-19221Scopus ID: 2-s2.0-84924651692OAI: oai:DiVA.org:hig-19221DiVA, id: diva2:806151
Konferens
13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014, 7-12 July 2014, Hong Kong
Tillgänglig från: 2015-04-17 Skapad: 2015-04-17 Senast uppdaterad: 2018-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Scopus

Personposter BETA

Björling, Mikael

Sök vidare i DiVA

Av författaren/redaktören
Björling, Mikael
Av organisationen
Miljöteknik
Strömningsmekanik och akustik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 331 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf