hig.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluating indoor environment of a retrofitted multi-family building with improved energy performance in Sweden
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.
Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.
Högskolan i Gävle, Akademin för teknik och miljö, Avdelningen för bygg- energi- och miljöteknik, Energisystem. Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.ORCID-id: 0000-0003-3472-4210
2015 (engelsk)Inngår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 102, s. 32-44Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The building sector within both the EU and Sweden accounts for about 40% of total energy use. It is therefore important to introduce energy efficiency measures in this sector in order to meet the national implementation of the Building Performance Directive. Retrofits that result in improved energy performance are important in order to meet national energy targets, but the impact on the indoor environment has to be considered. Properly chosen energy efficiency measures may affect the indoor environment positively. One retrofitted multi-family building, located in the city of Linköping, Sweden, was chosen as the study object. The building represents a common type of construction in Sweden. This study presents an evaluation of both the indoor environment and energy use of the retrofitted building in comparison with a similar non-retrofitted building from the same area. The results show that the building has potential to reach a 39% reduction of space heating demand. The indoor environment has been improved compared to the non-retrofitted building. Adding external blinds from 15 May to 15 September between 10am-12pm on the east side and 12pm-3pm on the west side seems to be the best option for improving the indoor climate during summer. 

sted, utgiver, år, opplag, sider
2015. Vol. 102, s. 32-44
Emneord [en]
Building energy simulation, Energy use, Indoor environment, Multi-family building, Retrofit, Buildings, Retrofitting, Building energy simulations, Building Performance Directive, Building sectors, Efficiency measure, Energy performance, Energy efficiency
HSV kategori
Identifikatorer
URN: urn:nbn:se:hig:diva-19956DOI: 10.1016/j.enbuild.2015.05.021ISI: 000358458100003Scopus ID: 2-s2.0-84930947067OAI: oai:DiVA.org:hig-19956DiVA, id: diva2:838826
Forskningsfinansiär
Swedish Energy AgencyTilgjengelig fra: 2015-07-01 Laget: 2015-07-01 Sist oppdatert: 2018-03-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Liu, LinnMoshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Liu, LinnMoshfegh, Bahram
Av organisasjonen
I samme tidsskrift
Energy and Buildings

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 311 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf