Assessment of Airflows in a School Building with Mechanical Ventilation Using Passive Tracer Gas Method
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy system.ORCID iD: 0000-0002-5822-4838
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy system.ORCID iD: 0000-0001-9076-0801
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Environmental engineering.ORCID iD: 0000-0002-8985-2562
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy system.ORCID iD: 0000-0003-3472-4210
2017 (English)In: Mediterranean Green Buildings & Renewable Energy: Selected Papers from the World Renewable Energy Network’s Med Green Forum / [ed] Sayigh, Ali, Springer, 2017, 1, 619-631 p.Chapter in book (Refereed)
Abstract [en]

The focus of this study is to assess the airflows in a school building built in 1963 in Gävle, Sweden, which is subject to energy conservation measures (ECMs) in a forthcoming renovation. Today, the school building is mainly ventilated by several mechanical ventilation systems, which are controlled by a constant air volume (CAV) strategy. Schedules and presence sensors impose a high operation mode during the day and a low operation mode at night, on weekends and on holidays. The homogeneous tracer gas emission method with passive sampling is used to measure the average local mean age of air (τ) during different operation modes. Temperature, relative humidity and CO2 concentration are simultaneously measured. The calculated relative uncertainty for the average local mean age of air in every measured point is approx. ±20 %. The results during low operation mode show an average value of τ of approx. 8.51 h [corresponding to 0.12 air changes per hour (ACH)], where τ in various zones ranges between 2.55 and 16.37 h (indicating 0.06–0.39 ACH), which is related to the unintentional airflow in the school. The results during mixed operation mode show an average value of τ of approx. 4.60 h (0.22 ACH), where τ in various zones ranges between 2.00 and 8.98 h (0.11–0.50 ACH), which is related to both unintentional and intentional airflows in the school. Corridors, basement and attic rooms and entrances have lower τ compared to classrooms, offices and other rooms. High maximums of the CO2 concentration in some rooms indicate an imbalance in the mechanical ventilation systems. During a regular school week of mixed operation, which includes both high and low operation modes, it is found that mainly the low operation modes show up in the results. The dynamics of the highly varying airflows in the building cannot be identified using the passive sampling technique.

Place, publisher, year, edition, pages
Springer, 2017, 1. 619-631 p.
Keyword [en]
Homogeneous tracer gas emission technique, Local mean age of air, Air change rate, Air leakage, School building
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-24006DOI: 10.1007/978-3-319-30746-6_47Scopus ID: 2-s2.0-85029047826Libris ID: 19983693ISBN: 978-3-319-30745-9 (print)ISBN: 978-3-319-30746-6 (electronic)OAI: oai:DiVA.org:hig-24006DiVA: diva2:1095276
Available from: 2017-05-12 Created: 2017-05-12 Last updated: 2017-10-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Steen Englund, JessikaAkander, JanBjörling, MikaelMoshfegh, Bahram
By organisation
Energy systemEnvironmental engineering
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 114 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf