hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Hur kan värmeenergianvändningen i en fastighet med ett högt energiuttag och komplicerat energisystem sänkas och hur påverkar det uppvärmningskostnaden: En fallstudie gjord på Gävle Energi ABs huvudkontor
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy system.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Gävle Energi AB har lagt fram förslag på en ny prismodell som är säsongsberoende och ger en bättre återspegling av konsumenternas riktiga energiuttag. Den nya prismodellen är uppdelad i ett effektpris och en energiavgift. Effektpriset baseras på energiuttaget i fastigheten vid en utomhustemperatur på -10°C. Energipriset varierar över året och har till uppgift att återspegla kostnaden för att producera värmeenergin, det är meningen att den ska vara kostnadsneutral för producenten. Har kunden ett väl fungerande värmesystem med låga effektuttag blir kostnaden lägre och vice versa. Kunder som riskerar att erhålla en förhöjd kostnad är de med mer avancerade energisystem.

I fallstudien undersöks Gävle Energi ABs huvudkontor på Näringen i Gävle. Huvudkontoret är en fastighet som har ett komplicerat energisystem och högt energiuttag vilket gör att det riskerar att få förhöjd avgift. För att undersöka hur det kan undvikas har en energikartläggning främst på värmesystemet i fastigheten utförts. Målet var att hitta sätt att sänka både energibehovet och kapacitetsbehovet.

I fastighetens energisystem finns det fyra stycken ventilationsaggregat, golvvärme, fönsterapparater, luftvärmare, två kylmaskiner samt frikyla. All tillförd värme i fastigheten kommer från fjärrvärmen. För de mätdata som inte finns tillgängliga görs rimliga antaganden, för att sedan stödja teorierna kompletteras dessa med beräkningar.

Det mest okomplicerade sättet att få ner kostnaden har visat sig vara genom att sänka inomhustemperaturer. Efter sänkning av inomhustemperaturen med 1°C samt temperatursänkning i garaget erhålls ett nytt kapacitetsbehov på 4 720 kWh/dygn. Vilket kan jämföras med det ursprungliga kapacitetsbehovet som låg på 5 011 kWh/dygn. Den totala energibesparingen för dessa åtgärder uppgår till drygt 51 MWh.    

Det finns också en del oväntade åtgärder där överskottsvärme från kylkompressorn kan återanvändas. Förändrade luftflöden i ventilationen kan också ge stora kostnadsreduceringar på både energi och effektpriset.

Abstract [en]

Gävle Energi AB has put forward proposals for a new pricing model that is seasonal dependent and provides a better reflection of consumers' real energy outages. The new pricing model is divided into an power price and an energy price. The power price is based on the energy consumption of the property at an outdoor temperature of -10°C. The energy price varies over the year and is intended to reflect the cost of producing the heat energy, which is intended to be cost neutral for the producer. If the customer has a well-functioning heating system with low power output, the cost will be lower and vice versa. Customers who are at risk of getting an increased cost are those with more advanced energy systems.

In the case study, Gävle Energi AB's head office is being investigated. The head office is a property that has a complicated energy system and high energy output, which makes it possible to get an increased fee. In order to investigate how it can be avoided, an energy survey has mainly been carried out on the heating system in the property. The goal was to find ways to reduce both the energy demand and the capacity requirement.

In the property's energy system there are four ventilation units, underfloor heating, windows, air heaters, two cooling machines and free cooling. All added heat in the property comes from district heating. For the measurement data that are not available, reasonable assumptions are made, and then supporting the theories are supplemented by calculations.

The most uncomplicated way to reduce costs has been shown by lowering indoor temperatures. After lowering the indoor temperature by 1°C and a temperature reduction in the garage, a new capacity requirement of 4 720 kWh/day will be obtained. Compared to the original capacity requirement of 5 011 kWh/day. The total energy saving for these measures amounts to around 51 MWh. There are also some unexpected measures where excess heat from the refrigeration compressor can be reused. Changed airflows in the ventilation can also cause major cost reductions on both energy and power prices.

Place, publisher, year, edition, pages
2017. , 72 p.
Keyword [sv]
energieffektivisering, värmesystem, fjärrvärme
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:hig:diva-24259OAI: oai:DiVA.org:hig-24259DiVA: diva2:1110337
External cooperation
Gävle Energi AB
Subject / course
Energy systems
Educational program
Energy systems – bachelor’s programme (in eng)
Presentation
2017-06-07, 99:322, Högskolan i Gävle, Gävle, 10:30 (Swedish)
Supervisors
Examiners
Available from: 2017-06-16 Created: 2017-06-15 Last updated: 2017-06-18Bibliographically approved

Open Access in DiVA

fulltext(5141 kB)14 downloads
File information
File name FULLTEXT01.pdfFile size 5141 kBChecksum SHA-512
2664b767eea908cfc84a4dbf8baad8e531b8e268982c771a530dba7ac53c55513e3f22011bcbcc41cb131147479e3fa923e84f5392ccad2cbc2cdefbd342d3c5
Type fulltextMimetype application/pdf

By organisation
Energy system
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 14 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 74 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf