Integrering av styrsystem till SIMATIC PCS 7: En fördjupning i SIMATIC PCS 7/Open OS
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Electronics, Mathematics and Natural Sciences.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Denna studie ämnar undersöka hur styrsystem från Siemens som inte ingår i ordinarie produktbibliotek till deras processkontrollsystem PCS 7 kan integreras. Integreringen kommer utföras med hjälp av ett tilläggspaket till PCS 7, SIMATIC PCS7/Open OS. Styrsystemen som ska integreras i detta arbete är vanligt förekommande på industrier idag, SIMATIC S7-300/1500. Dessa styrs normalt inte via processkontrollsystem, mer vanligt är att de styrs lokalt via en operatörspanel intill maskinen. Genom att integrera dessa till processkontrollsystem kommer de att kunna styras från större kontrollrum, samtidigt som fördelarna med att integrera moderna styrsystem med ny teknik erhålls i produktionen.

En annan del av studien har för avsikt att jämföra tidigare fall av liknande integreringar där andra typer av tekniker har använts. Dessa fall har visat att det finns idag standardiserade tekniker för att integrera enstaka fältenheter så att dessa kan hanteras av övergripande kontrollsystem. I en av studierna som undersöks, där det har gjorts försök att integrera funktionen av ett styrsystem som kontrollerar flertalet fältenheter, finns det enligt studien begränsningar i tekniken som används. Enligt Siemens AG ska dock tillägget SIMATIC PCS 7/Open OS klara att integrera ett styrsystem med dess fulla funktionalitet till processkontrollsystemet PCS 7.

Resultatet av arbetet visar att integrering av styrsystemen till PCS 7 genom att använda tillägget är möjlig och styrsystemets fulla funktion kunde erhållas från ett PCS7-HMI. För att integreringen med tilläggspaketet ska ske smidigare rekommenderas att förberedelser, såsom att skapa bibliotek både i PCS 7 och i styrsystemet utförs innan integreringsarbetet påbörjas. Biblioteken bör innehålla funktionsblock förexempelvis motordrifter i styrsystemet och grafikelement som motsvarar dessa i PCS7.

Abstract [en]

This study will focus on how Siemens controllers that are not listed in the productlibrary of the process control system PCS 7, can be integrated. The integration willbe performed using an option for PCS 7 (SIMATIC PCS 7/Open OS). The controllers to be integrated in this work are commonly found in industries today, the Siemens controllers SIMATIC S7-300/1500. These are usually not controlled from a processcontrol system, they are more commonly controlled via an operator panel next to the machine. By integrating these controllers into the process control system, they can be controlled from larger control rooms, and the production will acquire the benefits of using modern controllers.

Previous cases with similar components, where other integration techniques was used has been evaluated. In these cases the integration have shown that there are today standardized techniques for integrating single field devices so that they can be managed by process control systems. In another study investigated, where attempts have been made to integrate the function of a controller that is controlling several field devices, the study showed limitations in the technique used. According to Siemens AG however, SIMATIC PCS 7/Open OS will be able to integrate acontroller with its complete functionality into the process control system PCS 7.

The result of the work shows that integration of the controllers to PCS 7 by using the option package is possible, and the controller could be fully operated from a PCS 7-HMI. In order to make the integration with the optional package more user-friendly, it is recommended that preparations be made before integrating. Such as preparing a library in both PCS 7 and in the controller to be integrated, which are containing for example function blocks in the controller side and graphic elements corresponding to these function blocks in the PCS 7-HMI side.

Place, publisher, year, edition, pages
2017. , p. 30
Keywords [en]
Integrating, controller, PLC, PCS, Siemens, SIMATIC PCS 7, SIMATIC PCS 7/Open OS, SIMATIC S7-1500
Keywords [sv]
Integrering, styrsystem, PLC, PCS, Siemens, SIMATIC PCS 7, SIMATIC PCS 7/Open OS, SIMATIC S7-1500
National Category
Robotics
Identifiers
URN: urn:nbn:se:hig:diva-25294OAI: oai:DiVA.org:hig-25294DiVA, id: diva2:1157607
External cooperation
Sandvik Materials Technology; ÅF Industry AB
Subject / course
Electronics
Educational program
Högskoleingenjör
Supervisors
Examiners
Available from: 2017-11-16 Created: 2017-11-16 Last updated: 2017-11-16Bibliographically approved

Open Access in DiVA

fulltext(2809 kB)516 downloads
File information
File name FULLTEXT01.pdfFile size 2809 kBChecksum SHA-512
692a492d7576bea086d56f83301181ae5d4c64077e8e57cecd4b15421b5cc43ba4e38b62ef564a15ab50d75a15c00bc04b525409424546734df7b2f124c4daac
Type fulltextMimetype application/pdf

By organisation
Department of Electronics, Mathematics and Natural Sciences
Robotics

Search outside of DiVA

GoogleGoogle Scholar
Total: 516 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1044 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf