hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
On the performance of LCC optimization software OPERA-MILP by comparison with building energy simulation software IDA ICE
Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.
Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy system. Division of Energy Systems, Department of Management and Engineering, Linköping University, Linköping, Sweden.ORCID iD: 0000-0003-3472-4210
2018 (English)In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 128, p. 305-319Article in journal (Refereed) Published
Abstract [en]

From an economic point of view, it is crucial to minimize the life cycle costs (LCC) of buildings undergoing energy renovations, hence an optimization approach is needed. Building energy use and power demand as well as energy efficiency measures are important issues while performing an LCC optimization. Thus it is of great importance to accurately predict the building energy use and power demand before and after energy renovation. This paper aims to address the performance of an in-house LCC optimization software, OPERA-MILP, which has a rather fast optimization procedure. The aim is fulfilled through comparison with building energy simulation software IDA ICE before and after cost-optimal energy renovation. Three historic buildings with different layout and construction properties are used as a case study. The results show good agreement in the calculations of buildings’ power demand and energy use between OPERA-MILP and IDA ICE. The percentage difference in calculated annual energy use and buildings’ power demand with OPERA-MILP compared to IDA ICE is shown to be maximum 11% and 8% for the studied climate zones, respectively. Total impact on LCC is estimated to be equal to or less than 8%.

Place, publisher, year, edition, pages
Elsevier Ltd , 2018. Vol. 128, p. 305-319
Keywords [en]
Building energy simulation, Energy renovation, Historic buildings, IDA ICE, LCC optimization, OPERA-MILP, Computer software, Electric power utilization, Energy efficiency, Ice, Integer programming, Life cycle, Building energy simulations, Buildings, computer simulation, construction method, historic building, life cycle analysis, numerical model, optimization, performance assessment, software
National Category
Energy Systems
Research subject
Sustainable Urban Development
Identifiers
URN: urn:nbn:se:hig:diva-25837DOI: 10.1016/j.buildenv.2017.11.012ISI: 000423004900027Scopus ID: 2-s2.0-85037059457OAI: oai:DiVA.org:hig-25837DiVA, id: diva2:1167900
Funder
Swedish Energy Agency, P31669-3Available from: 2017-12-19 Created: 2017-12-19 Last updated: 2022-09-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Moshfegh, Bahram

Search in DiVA

By author/editor
Moshfegh, Bahram
By organisation
Energy system
In the same journal
Building and Environment
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 359 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf