The effect of false ceiling on the cooling capacity of passive chilled beams
University of Gävle, Department of Technology and Built Environment, Ämnesavdelningen för inomhusmiljö. (Ventilation och Luftkvalitet)
University of Gävle, Department of Technology and Built Environment, Ämnesavdelningen för inomhusmiljö. (Ventilation och Luftkvalitet)ORCID iD: 0000-0003-1121-2394
Responsible organisation
2009 (English)In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 44, no 7, p. 1426-1430Article in journal (Refereed) Published
Abstract [en]

Passive chilled beams are often used to provide cooling or additional cooling when the ventilation system cannot cope with the whole cooling load. The advantage of passive cooling is that it is a silent cooling. Often the chilled beams are installed above a false ceiling and thereby the room is subdivided into two compartments. From the chilled beam a plume is generated. Make-up air (return air) needs to flow into the upper compartment to substitute the airflow generated by the chilled beam. Therefore openings for this purpose are installed in the false ceiling. Small openings constitute a resistance to the flow and the locations of the openings affect the flow pattern. The overall performance was studied in a mock-up of a real office by changing both the size and position of the openings for the make-up air. A uniform heating source was arranged by covering the floor with a heating foil. The best location and size of the openings were explored by both recording the heat absorbed by the beam and the temperature in the room. Minimum temperature attained in the room is the signature of the most efficient cooling. To achieve efficient cooling with a uniform floor-based heating source, two conditions must be fulfilled: a) the return opening area must be at least equal to the horizontal area of the chilled beam; b) the return air openings must be located at the perimeter of the room. In general we can expect conditions a) and b) to be applicable irrespective of type of heat, but for point sources we could achieve the best cooling by placing the return air opening above the heat source.

Place, publisher, year, edition, pages
2009. Vol. 44, no 7, p. 1426-1430
Keywords [en]
passive chilled beams, cooling capacity, false ceiling
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-2019DOI: 10.1016/j.buildenv.2008.06.017ISI: 000264514700015Scopus ID: 2-s2.0-60749100101OAI: oai:DiVA.org:hig-2019DiVA, id: diva2:118681
Available from: 2008-06-18 Created: 2008-06-18 Last updated: 2020-11-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Sandberg, Mats

Search in DiVA

By author/editor
Sandberg, Mats
By organisation
Ämnesavdelningen för inomhusmiljö
In the same journal
Building and Environment
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 1542 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf