Applications with wide bandwidth and high center frequencies force the analog to digital converter (ADC) to be active in a working range with less dynamic performance in relation to lower frequency bands. However using under-sampling techniques in combination with post-correction methods enable a combination of high sampling rate, wide bandwidth and low distortion. In this paper the employed dynamic post-correction is a combination of look-up tables and model based correction. The results are mainly based on measurements on a 12 bit 210 MSPS ADC. The improvement in total harmonic distortion and spurious free dynamic range are acceptable over a wide frequency range and it is robust to variations in amplitude.
IMTC 2007. 2007 IEEE Instrumentation and measurement technology conference, Warsaw, Poland, May 1-3, 2007