Ram pump hydraulic air test. Pressure conditions and flow measurements: Experimental research and case study
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering.
2018 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

This study consists of the development of a ram pump, which will allow the pumping of water without the need of external energy sources. It is considered an analysis of interest since, once it is finished; it can be applied in reality improving and facilitating different activities related to agriculture and health.

Previous studies have been made related to the ram pump; however, in this case, it is intended to understand the system that has been built in the laboratory in order to find the best combination of parameters that will lead to obtain the highest possible efficiency. 

The study will be carried out by studying scientific literature and by experimenting in the laboratory. Encompassing the experimental and literary field, it is expected to understand perfectly the advantages and disadvantages of the ram pump in order to determine if it is worth it to install in certain places.

After the study, the most favourable parameters for the operation of the Bruzaholms Bruk pump have been obtained. It has been found that the use of a longer drive pipe favours the operation of the system, as it is possible to obtain a higher efficiency, although it must be taken into account that the mentioned length needs to be controlled, as it could reduce the working rhythm of the pump. It has also been seen that the pump gives better results if the impulse valve is completely opened. Finally, it has been proven that, as long as the height difference between the two tanks is enough, increasing the height of the water source will favour the operation of the system.

Place, publisher, year, edition, pages
2018. , p. 41
Keywords [en]
Ram pump, water hammer, pressure, efficiency, installation, drive pipe, delivery pipe, impulse valve
National Category
Energy Engineering Fluid Mechanics and Acoustics
Identifiers
URN: urn:nbn:se:hig:diva-26897OAI: oai:DiVA.org:hig-26897DiVA, id: diva2:1216118
Subject / course
Energy systems
Educational program
Energy systems – master’s programme (one year) (swe or eng)
Supervisors
Examiners
Available from: 2018-06-12 Created: 2018-06-11 Last updated: 2018-06-12Bibliographically approved

Open Access in DiVA

fulltext(1930 kB)66 downloads
File information
File name FULLTEXT01.pdfFile size 1930 kBChecksum SHA-512
968666856e46bd9abb2449fe414d0587b833f733ed58ec4d3ce5d971329716c9b9cc289706c5ad19b1dc4d6dcd1c87a490a5ace2a174d10f79c0a90fd1674c23
Type fulltextMimetype application/pdf

By organisation
Department of Building, Energy and Environmental Engineering
Energy EngineeringFluid Mechanics and Acoustics

Search outside of DiVA

GoogleGoogle Scholar
Total: 66 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 79 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf