Nära noll-energi-byggnaders energianvändning: Analys av solel, energieffektivisering och val av uppvärmingsform genom simuleringar av byggnader och energisystem
2017 (Swedish)Report (Other academic)Alternative title
Nära noll-energi-byggnaders energianvändning : Delrapport 2 inom projektet "Regelstyrd energi- och miljövärdering av byggnader" (Swedish)
Abstract [sv]

I EU-direktivet om byggnaders energiprestanda anges att det är upp till de en-skilda medlemsstaterna att definiera och införa begreppet nära-noll-energi-byggnader (NNEB). Mot bakgrund av bl.a. det reviderade direktivet om byggna-ders energiprestanda har Boverket utarbetat skärpta energihushållningskrav som gäller fullt ut från 1 januari 2013 (BBR 2012). Dessa bestämmer hur mycket energi som maximalt får användas för uppvärmning, komfortkyla, tapp-varmvatten samt fastighetsenergi. Icke eluppvärmda byggnader får ha en faktor 1,6 gånger högre specifik energianvändning än eluppvärmda byggnader, vilket resulterar i att en byggnad med värmepump kan uppföras betydligt mindre energieffektiv än en byggnad som värms med fjärrvärme. Solenergi och den värme som en värmepump tar från omgivningen och som används direkt i byggnaden räknas som energief-fektivisering. I Boverkets förslag till föreskrifter finns ingen beskrivning hur solel skall hanteras. Detta ger upphov till problem i byggnaders projekteringsfas.

I denna rapport har fokus legat på att genom simuleringar av energianvändning i byggnader illustrera problemen med definitionen av nära-noll-energi-byggnader. Följande konsekvensanalyser har genomförts:

  1. Belysa problemet med solcellssystemets påverkan på byggnadens specifika energianvändning för byggnader med olika uppvärmningssystem (bergvär-mepump och fjärrvärme)
  2. Belysa hur BBR och NNEB definitionen påverkar renoveringar med avseende på specifik energianvändning och värdera vilka åtgärder som är mest lön-samma för fastighetsägaren.
  3. Belysa hur kraven i NNEB definitionen påverkar valt uppvärmningssystem i nya byggnader inom fjärrvärmeområden.

Slutsatserna utifrån simuleringarna är följande:

Boverkets föreslagna nära nollenergibyggnadsdefinition förstärker möjligheten att bygga systemkombinationer med bergvärmepump och solenergisystem som ger byggnader med lågt primärenergital. En fjärrvärmeuppvärmd byggnads primär-energital påverkas marginellt av installationen av ett solenergisystem. Redan rela-tivt små solenergistorlekar ger huvuddelen av minskningen av primär-energitalet för alla systemkombinationer.

I Boverkets föreskriftsförslag finns inga skallkrav gällande renovering så dessa blir ej styrande när det gäller renoveringar.

NNEB definitionen eller föreskriftförslaget för kapitel 9 i Boverkets byggregler möjliggör att nya byggnader får väldigt låga primärenergital om de utrustas med bergvärmepump. Om denna systemutformning införs i byggnader inom fjärr-värmeområdet så riskerar det att leda till en ökning av globala koldioxidutsläpp om inte elen har relativt låga utsläppsvärden som t.ex. Nordisk mix.

Abstract [en]

The EU Directive on Energy Performance of Buildings states that it is up to the individual Member States to define and implement the concept of nearly zero-energy buildings (NZEB). Given the revised Directive on Energy Performance of Buildings, the National Board of Housing, Building and Planning (Boverket) has developed more stringent energy requirements active from January 1st, 2013 (BBR 2012). These requirements determine the maximum levels of energy which may be used for heating, comfort cooling, hot tap water and building electricity. Non elec-trically heated buildings may have a factor 1.6 times higher specific energy usage than electrically heated buildings, resulting in a building with heat pump can be erected significantly less energy efficient than a building heated by district heating. Solar energy (power or heat) and the heat that a heat pump takes from the sur-roundings used directly in the building count as energy efficiency. In the Board's proposed regulations there is no description of how solar electricity will be han-dled. This gives rise to problems in building planning phase.

In this report, focus has been set on using simulations of energy consumption in buildings to illustrate the problem of the definition of nearly zero-energy build-ings. The following impact assessments have been carried out:

  1. Highlight the problem of how the HVAC system affect the specific energy use of buildings using different heating systems (geothermal heat pump and dis-trict heating)
  2. Highlight how the BBR and NNEB definitions affects renovations in terms of specific energy use and evaluate the measures that are most profitable for the property owner.
  3. Highlight how the requirements of the NNEB definition affects the chosen heating systems in new buildings within the district heating area.

The findings based on the simulations are as follows:

The National Board of Housing, Building and Planning 's proposed near-zero en-ergy building definition enhances the ability to build systems combinations with geothermal heat pump and solar systems that provide buildings with low primary energy numbers. The primary energy number for a building heated by district heating is affected marginally by the installation of a solar energy system. Even relatively small solar system sizes provide the bulk of the reduction of primary energy number for all system combinations.

In the Board's regulatory proposals there are no mandatory requirements regard-ing renovation, thus they are not ruling regarding renovations.

The NNEB definition or regulation proposal for Chapter 9 of the Building Regula-tions makes it possible for new buildings to receive very low primary energy num-bers if equipped with geothermal heat pump. If the system design is introduced in buildings within the district heating area, it may lead to an increase in global car-bon dioxide emissions unless the CO2 emissions from electricity are moderate as for Nordic mix.

Place, publisher, year, edition, pages
Stockholm: Energiforsk AB , 2017. , p. 79
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-28273OAI: oai:DiVA.org:hig-28273DiVA, id: diva2:1255129
Projects
Regelstyrd energi- och miljövärdering av byggnader
Note

Finansiär Energiforsk AB

Available from: 2018-10-11 Created: 2018-10-11 Last updated: 2020-01-13Bibliographically approved

Open Access in DiVA

fulltext(2086 kB)132 downloads
File information
File name FULLTEXT01.pdfFile size 2086 kBChecksum SHA-512
a24b9419c881c854398409b4b872ae99128f815076012b7003055f350c7496858027cd90a9e609d83b923dc6fc0405502dff8e6332a2994df0540607035ca66d
Type fulltextMimetype application/pdf

Authority records BETA

Eriksson, Ola

Search in DiVA

By author/editor
Eriksson, Ola
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 132 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 148 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf