Fukttransport i auto-klaverad lättbetong: En teoretisk simulering
1998 (Swedish)Report (Other academic)
Abstract [sv]

Genom byggproduktdirektiven (CPD) ställs krav på byggnadsmaterialstillverkarna som innebär att byggnadsmaterial skall livslängdsdeklareras. Därför har en grupp av byggnadsmaterialstillverkare starta ett projekt i samarbete med KTH och Högskolan Gävle-Sandviken där man studerar nedbrytning av lättbetong.

Avsikten med denna rapport har varit att genomföra teoretiska simuleringar med avseende på fukttransport i en yttervägg av autoklaverad lättbetong. Simuleringarna har genomförts med ett PC-program kallat 1D-ham. Med PC-programmet har fuktflöden i en yttervägg under icke stationära förhållande (varierande utomhusklimat) simulerats med uppmätta klimatdata.

Resultaten från simuleringarna har visat att relativa fuktigheten är över 90 % stora delar av året i olika väderstreck i en yttervägg. I en södervägg har relativa fuktigheten i det närmaste varit konstant över 90 % cirka 25 mm in i väggen från ytterytan. I de övriga väggarna sjunker relativa fuktigheten under sommaren för att bli i det närmaste konstant i hela väggen under sensommaren.

Fukthalten i ytterväggen har för de skikt där relativa fuktigheten överstigit cirka 80 % varierat starkt. För skikten där relativa fuktigheten varit under cirka 80 % har fukthalten i det närmaste varit konstant.

På basis av simuleringsresultaten har följande slutsatser har dragits.

• Relativa fuktigheten kan vara i det närmaste 100 % under en del av ett år för en yttervägg i ett väderstreck.

• Fukthalten varierar starkt under ett år i den del av ytterväggen som är nära ytterytan.

• Relativa fuktigheten på sommaren är i det närmaste är konstant i hela ytterväggen

.• Temperaturvariationerna ökar i skikt nära väggens ytterytan, vilket beror på väggens värmekapacitet.

Abstract [en]

According to the constructive product directive (CPD) the building material producers are obligated to state the service life of theirs products. In Gävle has a group of producers of building material initiate a project in co-operation with KTH and university collage of Gävle-Sandviken where the service life of aerated auto claved lightweight concrete is studied.

The objective has been to undertake theoretical simulate the non-stationary moisture flow in a wall of aerated autoclaved lightweight concrete. The simulations has a PC-program called 1D-ham been performed.

The results show that the relative humidity (rh) is above 90 % in an outside wall in different quarters. In the south direction it exceeds above 90 % the year. However, the other quarters is below 90 %.

The moisture content has shown a strong variation in the part of the wall where the rh is above 80 %, when it is below 80 % is almost constant.

The following conclusion has been drawn

• Relative humidity is 100 % in the south direction of the wall a part time of the year.

• The moisture content has a strong variation in the part of the wall where the rh is above 80 %.

• The rh is almost constant in the hole wall during the summer

• The temperature variations increase with the distances from the inner surface. This depends on the heat capacity of the wall.

Place, publisher, year, edition, pages
Gävle: Högskolan i Gävle/Sandviken , 1998. , p. 28
Series
Working Paper / Högskolan Gävle-Sandviken, ISSN 1102-5476 ; 46
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hig:diva-28554OAI: oai:DiVA.org:hig-28554DiVA, id: diva2:1264418
Available from: 2018-11-20 Created: 2018-11-20 Last updated: 2018-11-20Bibliographically approved

Open Access in DiVA

No full text in DiVA

Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 48 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf