hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Lämplighetsundersökning av olika system för att producera kyla: Fallstudie för en fastighet med bageri, restaurang och kontor
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2020 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Kyla produceras med ett antal helt skilda metoder. Denna rapport och fallstudie tar hänsyn till fyra metoder för kylning, kompressordriven-, absorptions-, fri-, och fjärrkyla. En del i problematiken är att systemen har mycket olika tekniska utformningar och krav på fastigheten, så som geografi och närhet till stora tekniska system som fjärrvärme och fjärrkyla. Kylsystemen jämfördes för att finna vilket kylsystem som var lämpligast samt vilket som hade den mest gynnsamma taxeringen för fastigheten. Kylsystemens lämplighet bedömdes framförallt efter underhållsbehov, men även storlek och ljudnivå. Fastigheten som utgör examensarbetets studieobjekt har ett kylbehov på 150 kW, vilket attribueras ett bageri, restaurang, kontor samt kylbänkar m.fl. Dessa har ett kylbehov under framförallt fyra sommarmånader, där kylbänkar m.fl även har ett kylbehov under resterande året. Flera studier har gjorts och pekar på att kylbehovet i framtiden kommer att öka, även om en exakt prognos inte kan ges. Det är även tydligt att alla de ovan nämnda kylsystemslösningarna har en roll att spela framöver. Examensarbetet har framförallt använt sig av en litteraturstudie för att besvara frågeställningarna. För litteraturstudien användes hemsidor som Discovery och ScienceDirect. För att beräkna energiförbrukning, drifttider och total kostnad så har Microsoft Excel använts. Framförallt för kylproduktion med kompressor, där det givna referensaggregatet har fyra olika driftfall beroende på kylbehov, varav ett är kylproduktion med frikyla. För att vikta frikylans andel har klimatdata från SMHI (2020) använts. Programmet har även använts för att sammanställa de tabeller och figurer som presenteras i resultatet. Prisförslag har givits efter personliga kommunikation per e-mail och telefonintervjuer med energiproducenter och tillverkare av kylaggregat. Resultatet visade att fjärrkyla var det för studieobjektet mest lönsamma alternativet, det står även för det system som är lämpligast då det är helt underhållsfritt för kunden. Anledningen till dess lönsamhet tillskrevs framförallt dess låga investeringskostnad. Att använda Gavleån för ren frikyla visade sig inte vara möjligt då temperaturen i ån är för hög sommartid. Även absorptionskyla visade sig vara olämpligt för studieobjektet då temperaturen i det lokala fjärrvärmenätet är för låg samtidigt som investeringskostnaden blivit hög. För absorptionskyla hade ett extra system behövts installeras, vilket rapporten inte kunnat prissätta. Rapporten visar däremot att metoden att producera kyla med absorptionsaggregat har potential att under rätt förutsättningar ersätta kompressorkyla. Detta för att minska dels belastningen på elnätet samt som ett sätt att minska CO2-utsläpp globalt, genom export av elektricitet till Europa. Detta arbete visar att dagens teknik är begränsad men att framtida teknik visar sig ha potential. Rapporten fann även att vidare arbete med vinning kunnat utföras för att identifiera absorptionskylas expansionspotential.

Abstract [en]

Cooling is produced with several completely differentiated methods. This report and case study considers four different methods of cooling, vapor-compression-, absorption-, free- and district cooling. A part of the problem is that the systems have vastly different technical configuration and requirement of a facility, such as geography and vicinity to other big technical system such as district cooling and district heating. The cooling systems are compared to find the method that is most suitable and has the most beneficial assessment. The different methods suitablitiy was graded based on, noise level, size and required maintenance. The facility that constitutes this thesis study has a cooling demand of 150kW, which is attributed to a bakery, a restaurant, an office and cooling benches etc. These have a cooling demand during four summer months, where cooling benches etc also have a demand during the rest of the year. Multiple studies showcase and point out that the cooling demand will grow in the future, even if a precise prognosis is not made. It is also clear that these above-mentioned cooling systems have a continuing role to play going forward. This thesis has foremostly used a literature review to answer the research questions. For the review webpages such as Discovery and ScienceDirect was used. To calculate the energy consumption, running hours and total yearly cost Microsoft Excel was used. Especially when cool produced with the compressor unit. The reference unit has four different operating modes depending on the cooling demand, one of the modes is production with free cooling. To value the share and impact that free cooling has, Microsoft Excel is used in combination with statistical data from SMHI (2020). Microsoft Excel is also used to compile the tables and figures in the “results” section. The pricing published in this report is based on personal communications per e-mail and phone interviews with energy producers and manufacturers of different cooling units. The result of the thesis show that district cooling is the most beneficial solution for cooling the facility. As well as the most suitable system since it is completely maintenance free for a customer. The reason for its profitability is attributed to its low investment cost. Using the nearby river for free cooling was deemed impossible because of its high temperature during the summers. Using absorption cooling was also considered unsuitable for the case object because of the low temperature in the local district heating network during summer times, as well as the high investment cost required because of it. To make absorption cooling suitable an additional system for cooling the processes would have to be installed, which this report has not been able to price.

Place, publisher, year, edition, pages
2020. , p. 54
Keywords [en]
Vapor-compressor cooling, Free cooling, District cooling, Absorption cooling, Sustainable society, Restaurant, Bakery, Office
Keywords [sv]
Kompressorkyla, Frikyla, Fjärrkyla, Absorptionskyla, Hållbart samhälle, Restaurang, Bageri, Kontor
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-32530OAI: oai:DiVA.org:hig-32530DiVA, id: diva2:1438480
External cooperation
Swecon
Subject / course
Energy systems
Educational program
Energy systems – bachelor’s programme (in eng)
Supervisors
Examiners
Available from: 2020-06-22 Created: 2020-06-10 Last updated: 2020-06-22Bibliographically approved

Open Access in DiVA

fulltext(4649 kB)203 downloads
File information
File name FULLTEXT01.pdfFile size 4649 kBChecksum SHA-512
1f91008c0b2ec1064d87dc1fa8a7ec1834e58617c911796bea40fdcb6db78dbeffceb2a969aeb69bf2eb5aa6de601a24db938960e18d2b8a0e10d5cb3323aff9
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Östlin, Robert
By organisation
Energy Systems and Building Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 203 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 451 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf