Measurements of air temperatures close to a low-velocity diffuser in displacement ventilation using an infrared camera
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-2023-689x
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-3472-4210
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0003-1121-2394
2002 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 34, no 7, p. 687-698Article in journal (Refereed) Published
Abstract [en]

The near zone of supply air diffusers is very critical for the indoor climate. Complaints of draft are often associated with low-velocity diffusers in displacement ventilation because the air is discharged directly into the occupied zone. Today, the knowledge of the near zone of these air supply diffusers is insufficient, causing an increased need for better measuring methods and representation of the occupied zone.

A whole-field measuring technique has been developed by the authors for visualization of air temperatures and airflow patterns over a large cross-section. In this particular whole-field method, air temperatures are measured with an infrared camera and a measuring screen placed in the airflow. The technique is applicable to most laboratory and field test environments. It offers several advantages over traditional techniques; for example, it can record real-time images within large areas and capture transient events.

The purpose of this study was to conduct a parameter and error analysis of the proposed whole-field measuring method applied to a flow from a low-velocity diffuser in displacement ventilation. A model of the energy balance, for a solid measuring screen, was used for analyzing the influence of different parameters on the accuracy of the method. The analysis was performed with respect to the convective heat transfer coefficient, emissivity, screen temperature and surrounding surface temperatures.

Theoretically, the temperature difference between the screen and the ambient air was found to be 0.2–2.4 °C for the specific delimitation in the investigation. However, after applying correction the maximum uncertainty of the predicted air temperature was found to vary between 0.62 and 0.98 °C, due to uncertainties in estimating parameters used in the correction. The maximum uncertainty can be reduced to a great extent by estimating the convective heat transfer coefficient more accurately and using a screen with rather low emissivity.

Place, publisher, year, edition, pages
Elsevier, 2002. Vol. 34, no 7, p. 687-698
Keywords [en]
Thermography, Whole-field measurement, Infrared camera, Visualization, Air temperature, Airflow pattern
National Category
Energy Engineering
Research subject
Sustainable Urban Development
Identifiers
URN: urn:nbn:se:hig:diva-33237DOI: 10.1016/S0378-7788(01)00133-5OAI: oai:DiVA.org:hig-33237DiVA, id: diva2:1454430
Available from: 2020-07-16 Created: 2020-07-16 Last updated: 2020-11-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Cehlin, MathiasMoshfegh, BahramSandberg, Mats

Search in DiVA

By author/editor
Cehlin, MathiasMoshfegh, BahramSandberg, Mats
By organisation
Energy Systems and Building Technology
In the same journal
Energy and Buildings
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 271 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf