hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Nonlinear analysis of concrete-filled steel composite columns subjected to axial loading
Department of Civil and Structural Engineering, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia.ORCID iD: 0000-0002-9431-7820
Department of Civil and Structural Engineering, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia.
Department of Civil and Structural Engineering, Universiti Kebangsaan Malaysia, Bangi, Selangor, Malaysia.
2011 (English)In: Structural Engineering and Mechanics, ISSN 1225-4568, E-ISSN 1598-6217, Vol. 39, no 3, p. 383-398Article in journal (Refereed) Published
Abstract [en]

This paper investigates the nonlinear analysis of concrete-filled steel composite columns subjected to axial loading to predict the ultimate load capacity and behaviour of the columns. Finite element software LUSAS is used to conduct the nonlinear analyses. The accuracy of the finite element modelling is verified by comparing the result with the corresponding experimental result reported by other researchers. Nonlinear analyses are done to study and develop different shapes and number of cold-formed steel sheeting stiffeners with various thicknesses of cold-formed steel sheets. Effects of the parameters on the ultimate axial load capacity and ductility of the concrete-filled steel composite columns are examined. Effects of variables such as concrete compressive strength fc and cold-formed steel sheet yield stress fyp on the ultimate axial load capacity of the columns are also investigated. The results are shown in the form of axial load-normalized axial shortening plots. It is concluded from the study that the ultimate axial load capacity and behaviour of the concrete-filled steel composite columns can be accurately predicted by the proposed finite element modelling. Results in this study demonstrate that the ultimate axial load capacity and ductility of the columns are affected with various thicknesses of steel sheets and different shapes and number of stiffeners. Also, compressive strength fc of the concrete and yield stress fyp of the cold-formed steel sheet influence the performance of the columns significantly.

Place, publisher, year, edition, pages
2011. Vol. 39, no 3, p. 383-398
Keywords [en]
nonlinear analysis; concrete-filled steel composite column; finite element; ultimate axial load capacity; cold-formed steel sheeting stiffener; ductility
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-33959DOI: 10.12989/sem.2011.39.3.383ISI: 000292482900005Scopus ID: 2-s2.0-79960245358OAI: oai:DiVA.org:hig-33959DiVA, id: diva2:1467586
Available from: 2020-09-15 Created: 2020-09-15 Last updated: 2021-09-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Bahrami, Alireza

Search in DiVA

By author/editor
Bahrami, Alireza
In the same journal
Structural Engineering and Mechanics
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 183 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf