Energikartläggning av Montessoriskolan
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
2022 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Energianvändning stiger kontinuerligt varje år. Detta beror på ekonomisk tillväxtoch ökad befolkning. Byggnadssektorn förbrukade 40 % av den totala energianvändningen i Sverige. Minskning av energibehovet inom byggsektorn är viktigt föratt Sverige ska uppnå energimål för minskad energianvändning i framtiden. Därförär energieffektivitetsåtgärder i byggnader idag, utgör ett av huvudmålen för energipolitiken mot 2020-mål. För att identifiera aktuell energianvändning för en byggnad är en energikartläggning först steg. Energikartläggningen utförds i Gefle Montessoriskola i Gävle.Byggnaden består av bottenplan och kälarenplan. Skolbyggnaden Uppfördes påsextitalet vilket gör deras energianvändning intressant. Skolbyggnadens energikartläggning baserad på energiberäkningar, insamlingsdata och energisimuleringar. Detfinns olika åtgärder för energieffektivitet som kan genomföras om energieffektiviseringsåtgärder är lönsamt. I detta arbete beskrivs olika åtgärder för energieffektivisering i Gefle Montessoriskola. Med hjälp av programvara IDA ICE skapades basmodellen för skolbyggnaden och läggs insamlingsdata in i IDA ICE som simulerades under ett år. Den totalaelanvändningen av skolbyggnaden var cirka 85 032 kWh/år medan var fjärrvärmen325 227 kWh/år. Resultatet visade en stor minskning av energianvändningar som kan utföras olikaenergieffektiviseringsåtgärder i skolbyggnaden såsom byte av fönster, byte av belysningar och tillägg isolering på ytterväggar. Enligt resultat var värmeförluster viafönster store 88 634 kWh/år och förbättringar på fönstren kan vara ett effektivt sättatt minska energiförlusterna. Genom att göra en beräkning efter förbättringar reducerar värmeförluster till 61 991 kWh/år.Att tillägga mer isolering på yttervägg för att reducera värmeförluster. Vid tilläggsisolering minskar energianvändningen till 395 699 kWh/år.LED installation för varje utrymmen i byggnaden är ett sätt att minska energianvändningen och LED belysningen ge bra effektiv än nuvarande belysning. Byte tillLED minskar energianvändningen till 405 983 kWh/år.ivResultatet av studien visade att skolbyggnaden kan minska deras energianvändningmed 10 % med hjälp av de samtliga åtgärder. Ekonomiska aspekter har beaktatsvilket visar samband mellan energibesparing och ekonomiska vinst

Abstract [en]

Energy use is rising continuously every year. This is due to economic growth andincreased population. The construction sector consumed 40% of total energy use inSweden. Reducing energy needs in the construction sector is important for Swedento achieve energy goals for reduced energy use in the future. Therefore, energy efficiency measures in buildings today are one of the main goals of energy policytowards 2020 targets.To identify current energy use for a building, an energy mapping is first step. Theenergy survey is carried out at Gefle Montessori School in Gavle. The buildingconsists of ground floor and basement floor. The school building was built in thesixties, which makes their energy use interesting. The school building's energymapping based on energy calculations, collection data and energy simulations.There are various energy efficiency measures that can be implemented if energyefficiency measures are profitable.I have this work descriptions various measures for energy efficiency in Gefle Montessori School. With the help of software IDA ICE, the basic model was created forthe school building and collection data is put into IDA ICE which was simulatedfor one year. The total electricity use of the school building was approximately 85 032 kWh/year, while the district heating was 325 227kWh /year. The result showed a largereduction in energy use, which can be carried out various energy efficiencymeasures in the school building such a change of windows, replacement of lightingand additions insulation on exterior walls. According to results, heat losses via windows were large 88 634 kWh /year and improvements on the windows can be a wayto reduce energy losses. By making a calculation after improvements, reduce heatlosses to 61 991 kWh /year. To add more insulation to the outer wall to reduce heat loss. With additional insulation, energy consumption is reduced to 395 699 kWh /year.LED installation for every space in the building is a way to reduce energy use andLED lighting provide good efficiency than current lighting. Switching to LEDs reduces energy consumption to 405 983 kWh /year.viiiThe results of the study showed that the school building can reduce their energyuse by 10 % using all measures. Economic aspects have been taken into accountthat show the same between energy saving and economic profit.

Place, publisher, year, edition, pages
2022. , p. 57
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hig:diva-39686OAI: oai:DiVA.org:hig-39686DiVA, id: diva2:1687133
Subject / course
Energy systems
Educational program
Energy systems – bachelor’s programme (in eng)
Supervisors
Examiners
Available from: 2022-09-05 Created: 2022-08-13 Last updated: 2022-09-05Bibliographically approved

Open Access in DiVA

min_uppsats(2636 kB)202 downloads
File information
File name ATTACHMENT01.pdfFile size 2636 kBChecksum SHA-512
f361b6760148067d849111e27e7c1157e5c8f5556c3753152d589cf6c0941910c90662dd3de0c7d256b4507a955c5fb298beea23f13cdc1dba122b8b7e1fd8cf
Type attachmentMimetype application/pdf

By organisation
Energy Systems and Building Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 222 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf