hig.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental Investigation of Ultimate Shear Force Capacity of Glulam Reinforced with Glued-in Threaded Rods
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.ORCID iD: 0000-0002-9431-7820
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building Engineering, Energy Systems and Sustainability Science, Energy Systems and Building Technology.
Show others and affiliations
2023 (English)In: The Open Construction & Building Technology Journal, ISSN 1874-8368, Vol. 17, p. 1-12Article in journal (Refereed) Published
Abstract [en]

Abstract:

Background:

Glued-in threaded (GIT) rods have been considered an effective timber connection method having several advantages, such as high load-carrying capacity, great stiffness, and good fire resistance. This type of connection has widely been utilized in newly built modern timber structures and for reinforcing the existing ones.

Objective:

The purpose of this experimental research is to investigate how the ultimate shear force capacity (USFC) of glulam is affected if it is reinforced with GIT rods and to study the interaction between the glulam and GIT rods. The results of this research can help researchers and engineers to select a suitable method of reinforcing the glulam with GIT rods at a superior inclination angle (IA) to the fiber direction in order to achieve higher USFCs.

Methods and Experimental Tests:

A total of forty glulam samples were tested for failure. The experimental tests consisted of five different series of samples with eight samples in each series. Sample series 1 were unreinforced glulam. Sample series 2 and 4 were glulam reinforced with the GIT rods at two different IAs of 45° and 90° to the fiber direction, respectively. Sample series 3 and 5 were glulam reinforced in the same way as sample series 2 and 4, but they were split in the middle. The samples were tested for failure using a standard testing machine. The machine was connected to a computer that recorded all the values obtained from the tests.

Results:

The results of the study were obtained as force-displacement graphs. The stiffness of the samples and interaction between the glulam and GIT rods were also calculated. The results achieved from the experimental tests of different series were compared and discussed.

Conclusion:

The experimental tests resulted in a 12.5% increase in the average USFC of sample series 2. However, the average USFC of sample series 4 was not enhanced significantly. The interaction between the glulam and GIT rods was obtained as 31.8% for the samples with reinforcing at the IA of 45° to the fiber direction and 3.8% for the samples with reinforcing at the IA of 90° to the fiber direction. Reinforcing the glulam with the GIT rods demonstrated the potential of enhancing its USFC. However, reinforcing the glulam with the GIT rods at the IA of 45° to the fiber direction was found to be superior to reinforcing the glulam with the GIT rods at the IA of 90° to the fiber direction.

Place, publisher, year, edition, pages
Bentham , 2023. Vol. 17, p. 1-12
Keywords [en]
Ultimate shear force capacity, Glulam, Glued-in threaded rod, Timber, Connection, Beam.
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:hig:diva-41875DOI: 10.2174/18748368-v17-e230418-2022-20Scopus ID: 2-s2.0-85162759257OAI: oai:DiVA.org:hig-41875DiVA, id: diva2:1759498
Available from: 2023-05-26 Created: 2023-05-26 Last updated: 2023-07-10Bibliographically approved

Open Access in DiVA

fulltext(7052 kB)65 downloads
File information
File name FULLTEXT01.pdfFile size 7052 kBChecksum SHA-512
813f30a22c632d916440a4291f01a83fe433042d60265d652c7529ba76f6c10fc790f66990314ad103d81f68a9be4a9f910cbe515591c3689ade8d87fd47ec65
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Bahrami, AlirezaEriksson, Bengt

Search in DiVA

By author/editor
Bahrami, AlirezaBlomberg, EmilBoqvist, SimonLauridsen, MarkusEriksson, Bengt
By organisation
Energy Systems and Building Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 65 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 421 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf