hig.sePublications
Planned maintenance
A system upgrade is planned for 24/9-2024, at 12:00-14:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Newly Designed Supply Diffuser for Industrial Premises
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy engineering. Linköping University, Department of Management and Engineering, Division of Energy Systems, Sweden.
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy engineering. Linköping University, Department of Management and Engineering, Division of Energy Systems, Sweden.ORCID iD: 0000-0003-3472-4210
University of Gävle, Faculty of Engineering and Sustainable Development, Department of Building, Energy and Environmental Engineering, Energy engineering. Linköping University, Department of Management and Engineering, Division of Energy Systems, Sweden.
2010 (English)In: The International Journal of Ventilation, ISSN 1473-3315, E-ISSN 2044-4044, Vol. 9, no 1, p. 59-67Article in journal (Refereed) Published
Abstract [en]

The results of this investigation revealed the airflow distribution from a new design of supply diffuser under non-isothermal conditions. To illustrate the indoor climate parameters in the occupied zone, for both the heating and cooling seasons, an experimental investigation was carried out in industrial premises. The indoor climate was explored at ankle, waist and neck levels for a standing person at different positions, to determine the variation of the thermal comfort indexes and draught rating (DR) with position in the facility. The observed PPD and DR values indicate acceptable levels of thermal comfort in the facility for both summer and winter cases. The conclusion can be drawn that well-distributed airflow saves energy by removing the need for an additional heating and cooling systems during cold and hot weather seasons.

Place, publisher, year, edition, pages
2010. Vol. 9, no 1, p. 59-67
Keywords [en]
industrial ventilation, experimental investigation, indoor climate, supply diffuser
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hig:diva-10272DOI: 10.1080/14733315.2010.11683867ISI: 000279036000006Scopus ID: 2-s2.0-77953582933OAI: oai:DiVA.org:hig-10272DiVA, id: diva2:442568
Conference
9th International Conference on Industrial Ventilation Location: ETH, OCT 18-21, 2009 , Zürich, Switzerland
Available from: 2011-09-21 Created: 2011-09-21 Last updated: 2018-03-13Bibliographically approved
In thesis
1. A Ventilation Strategy Based on Confluent Jets: An Experimental and Numerical Study
Open this publication in new window or tab >>A Ventilation Strategy Based on Confluent Jets: An Experimental and Numerical Study
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

This study presents air distribution systems that are based on confluent jets; this system can be of interest for the establishment of indoor environments, to fulfill the goals of indoor climate and energy-efficient usage. The main objective of this study is to provide deeper understanding of the flow field development of a supply device that is designed based on wall confluent jets and to investigate the ventilation performance by experimental and numerical methods. In this study, the supply device can be described as an array of round jets on a flat surface attached to a side wall. Multiple round jets that issue from supply device apertures are combined at a certain distance downstream from the device and behave as a united jet or so-called confluent jets. Multiple round jets that are generated from the supply device move downward and are attached to the wall at the primary region, due to the Coanda effect, and then they become wall confluent jets until the floor wall is reached. A wall jet in a secondary region is formed along the floor after the stagnation region.

The characteristics of the flow field and the ventilation performance of conventional wall confluent jets and modified wall confluent jets supply devices are investigated experimentally in an office test room. The study of the modified wall confluent jets is intended to improve the efficiency of the conventional one while maintaining acceptable thermal comfort in an office environment. The results show that the modified wall confluent jets supply device can provide acceptable thermal comfort for the occupant with lower airflow rate compared to the conventional wall confluent jets supply device.

Numerical predictions using three turbulence models (renormalization group (RNG k– ε), realizable (Re k– ε), and shear stress transport (SST k– ω) are evaluated by measurement results. The computational box and nozzle plate models are used to model the inlet boundary conditions of the nozzle device. In the isothermal study, the wall confluent jets in the primary region and the wall jet in the secondary region, when predicted by the three turbulence models, are in good agreement with the measurements. The non-isothermal validation studies show that the SST k– ω model is slightly better at predicting the wall confluent jets than the other two models. The SST k– ω model is used to investigate the effects of the nozzle diameter, number of nozzles, nozzle array configuration, and inlet discharge height on the ventilation performance of the proposed wall confluent jets supply device. The nozzle diameter and number of nozzles play important roles in determining the airflow pattern, temperature field, and draught distribution. Increased temperature stratification and less draught distribution are achieved by increasing the nozzle diameter and number of nozzles. The supply device with smaller nozzle diameters and fewer nozzles yields rather uniform temperature distribution due to the dominant effect of mixing. The flow behavior is nearly independent of the inlet discharge height for the studied range.

The proposed wall confluent jets supply device is compared with a mixing supply device, impinging supply device and displacement supply device. The results show that the proposed wall confluent jets supply device has the combined behavior of both mixing and stratification principles. The proposed wall confluent jets supply device provides better overall ventilation performance than the mixing and displacement supply devices used in this study.

This study covers also another application of confluent jets that is based on impinging technology. The supply device under consideration has an array of round jets on a curve. Multiple jets issue from the supply device aperture, in which the supply device is positioned vertically and the jets are directed against a target wall. The flow behavior and ventilation performance of the impinging confluent jets supply device is studied experimentally in an industrial premise. The results show that the impinging confluent jets supply device maintains acceptable thermal comfort in the occupied zone by creating well-distributed airflow during cold and hot seasons.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2015. p. 78
Series
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 1671
Keywords
Multiple interacting jets, round jets, confluent jets, wall jet, ventilation strategy, air distribution system, air supply device, ventilation performance, thermal comfort, energy-saving potential, measurement, numerical predictions, RANS turbulence models, renormalization group (RNG k– ε), realizable (Re k– ε), and shear stress transport (SST k– ω)
National Category
Energy Engineering
Identifiers
urn:nbn:se:hig:diva-19369 (URN)10.3384/diss-diva-117442 (DOI)978-91-7519-063-1 (ISBN)
Public defence
2015-05-29, ACAS, Hus A, Campus Valla, 10:15 (English)
Opponent
Supervisors
Available from: 2015-05-26 Created: 2015-05-26 Last updated: 2018-03-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Janbakhsh, SetarehMoshfegh, BahramGhahremanian, Shahriar

Search in DiVA

By author/editor
Janbakhsh, SetarehMoshfegh, BahramGhahremanian, Shahriar
By organisation
Energy engineering
In the same journal
The International Journal of Ventilation
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 644 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard-cite-them-right
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • sv-SE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • de-DE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf